ArticleGland surgery2026
Development and validation of an Automated computed tomography segmentation model for thyroid nodules using a channel attention high-resolution network.
Article in Gland surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Thyroid nodules are highly prevalent. Accurate segmentation of thyroid nodules is a prerequisite for computed tomography (CT)-based radiomics and computer-aided diagnosis, but manual region-of-interest delineation is time-consuming, subjective, and difficult to standardize. Although ultrasound remains the first-line imaging modality for thyroid nodule assessment, contrast-enhanced CT is frequently used in selected patients who have complex anatomy, suspected local extension, or require preoperative evaluation. Current deep learning models suffer from insufficient boundary capture for irregular nodules and high computational complexity, which has led to a lack of clinically practical tools. This study aimed to develop and internally validate an efficient automated CT segmentation model for thyroid nodules. Methods: This single-center retrospective study included CT images from 500 patients with pathologically confirmed thyroid nodules (250 benign and 250 malignant). Patients were divided at the patient level into training, validation, and internal test sets comprising 350, 50, and 100 patients, respectively. Eligible patients had thyroid CT and histopathological confirmation, and manual lesion contours served as the ground truth for segmentation. We propose Channel Attention High-Resolution Network (CA-HRNet), which enhances High-Resolution Network (HRNet) with a Channel Feature Selection Module (CFSM) that dynamically fuses multi-scale features by retaining discriminative channels and pruning redundant features, balancing representational capacity and computational efficiency. The model was trained using Dice loss with the RAdam optimizer and data augmentation. Segmentation performance was evaluated using the Dice coefficient (DC) and intersection over union (IoU), and CA-HRNet was compared with U-Net, SegFormer, Transformer U-Net(TransUNet), DAC-Net, and HRNet. Test-time augmentation (TTA) was applied during inference. Results: The cohort had a median age of 48 years, 373 female patients (74.6%), and a median nodule diameter of 1.60 cm. On the internal test set, CA-HRNet + TTA achieved the best overall segmentation performance, with a DC of 78.6% and an IoU of 70.0%. Performance was higher for benign nodules (Dice, 85.5%) than for malignant nodules (Dice, 66.2%), reflecting the more irregular morphology and less distinct boundaries of malignant lesions. Ablation experiments showed that the combination of CFSM and Channel Attention Convolution Module (CACM) achieved the best accuracy-efficiency balance and reduced computational complexity by 73%, from 93.764 to 25.376 giga multiply-accumulate operations (Giga MACs). Qualitative assessment showed that CA-HRNet produced masks with improved boundary adherence and detail preservation compared with competing models. Conclusions: CA-HRNet achieved accurate and computationally efficient automated segmentation of thyroid nodules on a single-center internal CT test set. The model may support reproducible region of interest (ROI) generation for CT-based radiomics and computer-aided diagnosis; however, multicenter external validation and downstream diagnostic or prognostic testing are required before routine clinical implementation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.