Design and Technical Validation of a Novel O2 Mixed Fitting for Dual Connection in Medical Oxygen Delivery Systems.

Oscar Ivan Quintero Osorio, Berkan Basançelebi, Elinaldo da Conceição Dos Santos, Sergio I Prada, David Alexander Lemos, Andrés Felipe Domínguez, Antonio M Esquinas

Abstract read
In one paragraph

Article in Medical devices (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Oscar Ivan Quintero OsorioCentro de Investigaciones Clínicas, Fundación Valle del Lili, Cali, Colombia.ORCID 0000-0003-0562-7358
Berkan BasançelebiDepartment of Electroneurophysiology, Vocational School, Istanbul Medipol University, Istanbul, Turkey.ORCID 0000-0002-6277-6985
Elinaldo da Conceição Dos SantosDepartment of Biological and Health Sciences, Universidade Federal Do Amapá, Macapá, Brazil.ORCID 0000-0002-4039-2980
Sergio I PradaCentro de Investigaciones Clínicas, Fundación Valle del Lili, Cali, Colombia.ORCID 0000-0001-7986-0959
David Alexander LemosCentro de Investigaciones Clínicas, Fundación Valle del Lili, Cali, Colombia.ORCID 0009-0004-6324-9521
Andrés Felipe DomínguezPromPack S.A.S, Cali, Colombia.ORCID 0009-0002-3036-633X
Antonio M EsquinasIntensive Care Unit, Hospital Meseguer, NIV-ICM, Instituto Murciano de Investigación Biosanitaria, Murcia, Spain.ORCID 0000-0003-0571-2050

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Medical oxygen delivery systems require adaptable connection interfaces capable of supporting different clinical configurations during oxygen therapy. Integrating multifunctional connection mechanisms within a single component offers an opportunity to improve system versatility and connection management in respiratory care settings. Objective: To design and experimentally validate a novel dual-connection fitting for medical oxygen delivery, designated as the O2 Mixed Fitting, that enables simultaneous attachment of both a bubble humidifier and conventional oxygen tubing while remaining installed on the flowmeter. Methods: A comprehensive state-of-the-art review informed the conceptual development of the device. Iterative design refinement was performed using computer-aided design. The final device was manufactured by injection molding using medical-grade Acrylonitrile Butadiene Styrene. Validation included gas flow analysis, leak and pressure-holding tests, microbiological and physical stability evaluation under controlled climatic conditions, and sustainability assessment using a structured eco-design framework. Results: The integrated dual-connection mechanism enabled transition between humidified and non-humidified oxygen delivery without detachment from the flowmeter. Gas flow measurements remained within predefined accuracy tolerances, including ±0.5 L/min at low flows and ±10% at higher flows. No leakage was detected during pressure testing up to 10 psi. During the 12-month natural stability study, physical and microbiological parameters remained within predefined acceptance criteria under climatic zone IVb conditions. The eco-design assessment demonstrated favorable environmental performance. Conclusion: The O2 Mixed Fitting represents an innovative dual-connection solution for medical oxygen delivery applications. Laboratory validation confirmed structural integrity, flow stability, pressure resistance, and physical and microbiological stability under the evaluated conditions. The integrated design enhances functional versatility while maintaining full compatibility with existing clinical infrastructure. Further clinical and operational studies are warranted to evaluate its potential impact on patient care and clinical workflow.

Indexed as

biomedical engineeringbubble humidifiermedical device designmedical oxygenoxygen connectoroxygen therapy