Highlighting the Importance of Authentic Reference Chemicals in the Unambiguous Identification of Unknowns during Routine Sample Analysis─An OPCW Proficiency Test Case.

Carolyn J Koester, Teneile M Alfaro, David S Cho, Todd H Corzett, Mark L Dreyer, Saphon Hok, Derrick C Kaseman, Adele F Panasci-Nott, Alexander K Vu, Armando Alcaraz and 1 more

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Carolyn J KoesterPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.ORCID 0000-0002-3867-7872
Teneile M AlfaroPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.
David S ChoPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.
Todd H CorzettPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.
Mark L DreyerPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.
Saphon HokPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.
Derrick C KasemanPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.ORCID 0000-0003-2076-1264
Adele F Panasci-NottPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.
Alexander K VuPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.
Armando AlcarazPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.
Carlos A ValdezPhysical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California94550, United States.ORCID 0000-0002-8641-9077

Funding

U.S. Department of Energy DE-AC52-07NA27344
6 · The paper itself

Abstract

The unequivocal identification of unknown chemicals during routine sample analysis is a constant occurrence in the field of analytical chemistry. The process can be painstakingly tedious, particularly in situations where a tentatively identified unknown may possess isomeric counterparts yielding identical accurate mass values and very similar mass spectra. In this work, we present the experimental process involved in the correct identification of 1,4-oxathiane 4,4-dioxide and differentiation from its constitutional isomer, 2-hydroxyethyl vinyl sulfone, when present in a silica gel matrix featured in the 54th Environmental Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test. After discovering that the library-generated mass spectrum for 2-hydroxyethyl vinyl sulfone in a preliminary gas chromatography-mass spectrometry (GC-MS) analysis did not match the one from an authentic reference chemical, we embarked on an unknown structure determination campaign involving GC-MS, liquid chromatography-tandem mass spectrometry (LC-MS-MS), and nuclear magnetic resonance (NMR) spectroscopy. All of the information obtained, coupled to the synthesis of an authentic reference chemical, was used to determine the identity of the unknown as 1,4-oxathiane 4,4-dioxide. The process described in this work highlights the important role played by authentic reference chemicals in the identification of unknown chemicals during routine sample analysis.

Identifiers

PMID42443120
PMCPMC13450385

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked