Evidence map›Paper›PMID 42440539›Full record

ArticleFrontiers in veterinary science2026

RAMSMART: a low-invasive system for real-time automated multi-species monitoring of livestock activity in research trials.

Harmen P Doekes, Cees J Voesenek, Rineke de Jong, Ines Adriaens, Bing Han, Norbert Stockhofe-Zurwieden

Abstract read
In one paragraph

Article in Frontiers in veterinary science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Harmen P DoekesWageningen Bioveterinary Research, Wageningen University and Research, Lelystad, Netherlands.
Cees J VoesenekVORtech BV, Delft, Netherlands.
Rineke de JongWageningen Bioveterinary Research, Wageningen University and Research, Lelystad, Netherlands.
Ines AdriaensLivestock Technology Group, Department of Biosystems, Division of Animal and Human Health Engineering, KU Leuven, Leuven, Belgium.
Bing HanWageningen Bioveterinary Research, Wageningen University and Research, Lelystad, Netherlands.
Norbert Stockhofe-ZurwiedenWageningen Bioveterinary Research, Wageningen University and Research, Lelystad, Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The continuous and automated monitoring of animal activity with sensors can help to refine and improve the quality of animal experiments. The aim of this study was to develop a system for real-time automated multi-species monitoring of individual animal activity in research trials ("RAMSMART"), to test this system in terms of battery life and data completeness, and to demonstrate its added value. Methods: We used lightweight commercially available accelerometers with edge computing and uploaded self-written firmware to these accelerometers to calculate the vectorial dynamic body acceleration (VeDBA). The accelerometer is attached, for example, to an animal's ear tag. It then collects raw acceleration data (at a user-defined sampling frequency), calculates the mean VeDBA across a certain period (based on a user-defined updating interval) and creates a data packet with the VeDBA, which is then broadcasted (at a user-defined broadcasting frequency) through Bluetooth Low Energy to a nearby receiving device, e.g., a laptop. On this receiving device, data are stored in a SQLite database and regularly copied to a shared drive to enable (near) real-time visualization of results from outside animal facilities. Results: Battery life depended on the sampling frequency, the updating interval and the broadcasting frequency. For example, when the sampling frequency was kept constant at 12.5 Hz, and the broadcasting frequency at 4 Hz, an updating interval of 1 second or 1 minute resulted in a battery life of 15.9 days (± 1.0 days) or 47.7 days (± 1.9 days), respectively. To avoid missing data, a sufficiently high broadcasting frequency was needed and the distance between sensor and receiver should be limited (preferably to < 20 m), or a multiple receiver set-up could be used. We showcased RAMSMART in three infectious disease trials in pigs, sheep and calves, connecting the VeDBA with other clinical symptoms, and demonstrating the added value of this system for early detection of deviations in activity. Conclusion: RAMSMART provides a low-invasive, affordable, re-usable, generalizable and plug-and-play approach for routine and long-term real-time automated activity monitoring based on acceleration data of (particularly livestock) animals in research trials. The source code and documentation of RAMSMART are openly available.

Indexed as

accelerometrybehaviorearly warning systemlaboratory animalsprecision livestock farmingsensingwelfare monitoring

Identifiers

PMID42440539
PMCPMC13333429

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.