Evidence map›Paper›PMID 42439969›Full record

ArticleMikrochimica acta2026

Single source precursor-enabled NiS nanosheets on flexible carbon cloth for sensitive electrochemical detection of chloramphenicol in food and biological matrix.

Prajakta N Gaikwad, Payal Lingras, Abhijay Tatipaka, Shrawan Kumar, Souradyuti Ghosh, Chitra Gurnani

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Prajakta N GaikwadDepartment of Chemistry, Ecole Centrale School of Engineering, Mahindra University, Hyderabad, 500043, India.ORCID http://orcid.org/0009-0006-8485-2295
Payal LingrasSchool of Nanoscience and Biotechnology, Shivaji University, Kolhapur, 416004, India.ORCID http://orcid.org/0009-0007-9014-8867
Abhijay TatipakaDepartment of Chemistry, Ecole Centrale School of Engineering, Mahindra University, Hyderabad, 500043, India.ORCID http://orcid.org/0009-0003-4554-2647
Shrawan KumarCentre for Life Sciences, Mahindra University, Hyderabad, 500043, India.ORCID http://orcid.org/0000-0002-6572-1728
Souradyuti GhoshCentre for Life Sciences, Mahindra University, Hyderabad, 500043, India.ORCID http://orcid.org/0000-0002-8510-1171
Chitra GurnaniDepartment of Chemistry, Ecole Centrale School of Engineering, Mahindra University, Hyderabad, 500043, India. chitra.gurnani@mahindrauniversity.edu.in.ORCID https://orcid.org/0000-0003-2950-7393

Funding

DST-Anusandhan National Research Foundation (ANRF)-advanced research grant (ARG) ANRF/ARG/2025/002756/LSIIIT-iHub funding reference # H4-006
6 · The paper itself

Abstract

The successful low-temperature, in-situ solvothermal strategy for the direct growth of nickel sulfide (NiS) nanostructures on flexible, conductive carbon cloth (CC) using a single-source precursor, Ni[S₂P(OC₃H₇)₂] is reported. This solution-processed approach enables the formation of highly-quality, crystalline and stoichiometric NiS films with a distinctive fern-like, porous nanosheet morphology, providing abundant electroactive sites and facilitating rapid electron transfer. The as-fabricated NiS/CC electrode exhibits excellent electrochemical sensing performance toward CAP, with a wide linear detection range (0.001-300 µM), an ultra-low detection limit (0.0012 µM), and high sensitivity (0.23 mA µM⁻¹ cm⁻²). Additionally, the sensor demonstrates excellent reproducibility, long-term stability, and strong selectivity against potential interfering species. Furthermore, the real-sample analysis with the proposed sensor demonstrates accurate determination of CAP in milk, honey, eye drops, and fetal bovine serum (FBS), with desirable recovery. Collectively, these findings establish SSP derived nanostructured NiS films as a promising material platform for next-generation flexible electrochemical sensors for antibiotic detection.

Indexed as

Anti-Bacterial AgentsCarbonChloramphenicolElectrochemical TechniquesFood ContaminationNanostructuresNickelAnimalsCattleElectrodesHoneyLimit of DetectionMilkSulfidesAnti-Bacterial AgentsCarbonChloramphenicolNickelSulfidesAntibioticsElectrochemical detectionFlexible carbon clothFood safetyNanostructured NiSSingle source precursorSolution processed route

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.