Evidence map›Paper›PMID 42439949›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2026

Hounsfield unit threshold to predict lumbar fusion failure: a finite element study.

Dmitrii Sidorenko, Aleksandr Dol, Leonid Bessonov, Olga Leonova, Aleksandr Krutko, Dmitrii Ivanov

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Dmitrii SidorenkoLaboratory of digital medical technologies, Saratov State University, Saratov, Russian Federation.
Aleksandr DolLaboratory of digital medical technologies, Saratov State University, Saratov, Russian Federation.
Leonid BessonovLaboratory of digital medical technologies, Saratov State University, Saratov, Russian Federation.
Olga LeonovaNeurosurgery Department, Priorov National Medical Research Center of Traumatology and Orthopedics, Moscow, Russian Federation.
Aleksandr KrutkoNeurosurgery Department, Priorov National Medical Research Center of Traumatology and Orthopedics, Moscow, Russian Federation.
Dmitrii IvanovLaboratory of digital medical technologies, Saratov State University, Saratov, Russian Federation. ivanovdv.84@ya.ru.ORCID https://orcid.org/0000-0003-1640-6091

Funding

Innovation Assistance Fund project No. 5223GS1/91981
6 · The paper itself

Abstract

backgroundClinical studies have identified threshold HU values above which the risk of lumbar implant instability increases significantly; however, these threshold values have a very wide range. Furthermore, there is a lack of rationale for HU value thresholds based on biomechanical models to predict fusion failure. The purpose of the study is to provide biomechanical evidence for using an HU threshold to predict lumbar fusion failure.

methodsA fused model of the L4-L5 lumbar segment with screws and an interbody cage was developed. The model was then numerically investigated under standard static loading conditions (flexion, extension, lateral bending and axial rotation). The von Mises stresses were investigated in different elements of the fused segment, including the vertebral trabecular bone, with HU values varied from 256 to 90.

resultsThe highest stresses in the trabecular bone of the vertebral bodies were observed in the areas of contact with the screws during extension, lateral bending, and axial rotation in the lumbar segment. High stress concentrations were also found in the contact zones between the cage and the vertebral body during compression and extension. At HU values of 165 and above, the maximum stress in the vertebral trabecular bone was far below its ultimate strength. At HU = 140, the stress exceeds the ultimate strength during flexion. At HU = 125, the stress exceeds the ultimate strength under four loading conditions: flexion, extension, left bending, and clockwise axial rotation. The highest stresses in the cortical bone (100 MPa) and in the screws (180 MPa) did not reach critical values for cortical bone damage even at the lowest HU value of 90.

conclusionThis study suggests that, within the assumptions of this single-level finite element model, an HU value of approximately 125 represents a transition point at which trabecular bone stresses approach or exceed predicted strength under multiple loading modes in lumbar fusion with screw fixation. Cortical bone remained intact even at the lowest trabecular bone HU value of 90.

Indexed as

Lumbar VertebraeSpinal FusionBiomechanical PhenomenaBone ScrewsFinite Element AnalysisHumansStress, MechanicalFinite element analysisHounsfield unitsLumbar fusionTrabecular boneUltimate strengthVon Mises stress

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.