Evidence map›Paper›PMID 42437903›Full record

ArticleBMC musculoskeletal disorders2026

Effect of tendon-to-bone gap on adjustable- versus fixed-loop biceps tendon fixation.

Golovakha M L, Lisunov M S, Panchenko S P

Abstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Golovakha M LDepartment of Traumatology and Orthopedics, Zaporizhzhia State Medical and Pharmaceutical University, 26 Mariya Prymachenko Blvd, Zaporizhzhia, Zaporizhzhia Region, 69000, Ukraine. golovahaml@gmail.com.ORCID http://orcid.org/0000-0003-2835-9333
Lisunov M SDepartment of Traumatology and Orthopedics, Zaporizhzhia State Medical and Pharmaceutical University, 26 Mariya Prymachenko Blvd, Zaporizhzhia, Zaporizhzhia Region, 69000, Ukraine.ORCID http://orcid.org/0000-0002-4796-6019
Panchenko S PDepartment of Mechanical and Biomedical Engineering, Dnipro University of Technology, 19 Dmytro Yavornytskyi Avenue, Dnipro, Dnipropetrovsk Region, 49005, Ukraine.ORCID http://orcid.org/0000-0001-5826-3645

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDistal biceps tendon ruptures significantly impair forearm flexion and supination strength, particularly in active individuals. Suspensory fixation using cortical button devices is a widely accepted surgical approach. Adjustable-loop techniques allow maximal tendon-to-bone apposition, while fixed-loop methods are simpler but may leave a gap. Biomechanical differences between these techniques specific to the distal biceps tendon remain poorly investigated, especially given the unique loading patterns of the elbow compared to other joints.

methodsFinite element analysis was performed using ANSYS software. Three-dimensional models of the radius and distal biceps tendon were constructed from computed tomography data. Three configurations were compared: Model 1 (adjustable-loop with dense tendon-to-bone contact, 0 mm gap), Model 2 (fixed-loop with 1.0 mm gap), and Model 3 (fixed-loop with 5.0 mm gap). Cortical bone, tendon, suture, and titanium button properties were assigned based on literature values. A 500 N tensile load was applied at the proximal tendon boundary simulating 90° elbow flexion. Stress, strain, and displacement distributions were analyzed in the fixation system and tendon.

resultsMaximum tensile stresses in the fixation system were lowest in Model 1 (353 MPa) compared to Model 2 (407 MPa, + 15%) and Model 3 (423 MPa, + 20%). Tendon maximum stresses were similar across models (170-175 MPa), exceeding ultimate tendon strength only at isolated concentration nodes. Maximum strains in the fixation system followed the same pattern: 0.29 (Model 1), 0.33 (Model 2), 0.35 (Model 3). Maximum tendon displacements (d_t) were 5.4 mm (Model 1), 5.7 mm (Model 2), and 6.9 mm (Model 3), primarily due to suture elongation. The 90th percentile stresses (σ_P90) and strains (ε_P90) remained consistent across configurations. The superior biomechanical performance of the adjustable-loop technique primarily reflects its ability to achieve zero tendon-to-bone gap rather than the loop mechanism itself.

conclusionsSuspensory fixation with zero tendon-to-bone gap (achieved by adjustable-loop technique) demonstrated superior biomechanical performance, exhibiting lower peak stresses, strains, and displacements in the fixation system compared to fixed-loop techniques with gaps. These findings suggest improved construct stability with zero-gap apposition. Further in vitro cyclic loading studies and clinical validation are required.

Indexed as

Suture TechniquesTendon InjuriesTendonsBiomechanical PhenomenaElbow JointFinite Element AnalysisHumansStress, MechanicalTensile StrengthAdjustable loopBiomechanicsCortical button fixationDistal biceps tendon ruptureElbow jointFinite element analysisFixed loopSurgical treatment

Identifiers

PMID42437903
PMCPMC13647777

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.