Intra-vendor inter-scanner agreement of negative-HU measurements on fast kV-switching dual-energy CT virtual monoenergetic imaging: a phantom study.

Norimi Nishiyama, Takanori Masuda, Junnichi Nakagawa, Motohiro Tabchi, Ryota Yamanaka, Yoshinori Nagayasu, Yuta Fujiwara, Hiroyuki Ikenaga

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Norimi NishiyamaDepartment of Radiological Technology, Okayama Saiseikai General Hospital, 2-25, Kokutai-cho, Kita-ku, Okayama-shi, 700-8511, Okayama, Japan.
Takanori MasudaDepartment of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, 701-0193, Okayama, Japan. takanorimasuda@yahoo.co.jp.ORCID http://orcid.org/0000-0002-4164-4369
Junnichi NakagawaDepartment of Radiological Technology, Okayama Saiseikai General Hospital, 2-25, Kokutai-cho, Kita-ku, Okayama-shi, 700-8511, Okayama, Japan.
Motohiro TabchiDepartment of Radiology, Konko Hospital (Dojinkai Medical Corporation), 740 Uramishinden, Konko-cho, Asakuchi, 719-0104, Okayama, Japan.
Ryota YamanakaDepartment of Central Radiology, Japanese Red Cross Okayama Hospital, 2-1-1 Aoe, Kita-ku, Okayama, 700-8607, Okayama, Japan.
Yoshinori NagayasuDepartment of Radiology, Akaiwa Medical Association Hospital, 187-1 Shimoichi, Akaiwa, 709-0816, Okayama, Japan.
Yuta FujiwaraDepartment of Radiological Technology, Onomichi Municipal Hospital, Shintakayama, Onomichi, 722-8503, Hiroshima, Japan.
Hiroyuki IkenagaDepartment of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki, 701-0192, Okayama, Japan.

Funding

This work was supported by the Japanese Society of Radiological Technology Research Grant (FY 2024-2025). This work was supported by the Japanese Society of Radiological Technology Research Grant (FY 2024-2025).
6 · The paper itself

Abstract

The purpose of this study was to evaluate inter-scanner agreement and the dose-related stability of negative CT-number measurements on dual-energy CT virtual monoenergetic images under low-, mid-, and high-dose conditions. A custom phantom (sawdust, salad oil, cutting-fluid dilutions 100%-3%, and water) was scanned on two CT systems (Revolution CT and Discovery CT750 HD). DECT VMI (40-140 keV) was acquired at three CTDIvol-defined dose levels with five repeats per condition; CT numbers were measured using standardized central ROIs. Negative-HU materials increased monotonically with increasing keV on both scanners. At 70 keV, inter-scanner bias (ΔHU = Revolution - 750HD) increased as HU became more negative (r = 0.840), with an overall mean bias of - 3.57 HU and 95% limits of agreement of - 16.90 to 9.75 HU. The largest discrepancies were for sawdust (- 18.70 to - 20.09 HU). Water reference behavior differed by scanner and dose (Mean(|HU|) across 40-140 keV: 0.223 HU for Revolution vs. 2.464 HU for 750HD at low dose; 750HD remained offset at mid-high dose (2.319-2.508 HU). Dose stability at 70 keV was generally high, but 750HD showed low-dose deviations for 20% and 30% (ranges 12.13 and 12.27 HU) that diminished at mid-high dose. VMI shows predictable energy-dependent behavior for negative-HU materials, but inter-scanner bias increases for strongly negative values and low-dose conditions, and water-reference behavior can influence stability; scanner-aware interpretation and phantom-based harmonization are warranted for quantitative evaluation in the negative HU range.