Evidence map›Paper›PMID 42435083›Full record

ArticleClinical oral investigations2026

Sensor-derived wearing time predicts 3D orthodontic side effects during mandibular advancement therapy of obstructive sleep apnea.

Julia Krohn, Peter Proff, Helmut Hösl, Michael Arzt, Eva Paddenberg-Schubert, Sebastian Krohn

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Julia KrohnDepartment of Orthodontics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany. julia.krohn@klinik.uni-regensburg.de.
Peter ProffDepartment of Orthodontics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
Helmut HöslDepartment of Orthodontics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
Michael ArztCentre of Sleep Medicine, Department of Internal Medicine II, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
Eva Paddenberg-SchubertDepartment of Orthodontics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
Sebastian KrohnDepartment of Orthodontics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesDentally worn mandibular advancement devices (MAD) represent a second-line treatment option in patients with mild to moderate obstructive sleep apnea (OSA). Greater MAD adherence is associated with improved treatment success, but with increasing wearing time (WT) dental side effects might become more pronounced. Thus, objective assessment of WT and sophisticated methods for early detection of resulting adverse effects are necessary. MATERIALS AND

methodsIn this cross-sectional study 29 patients (8 female and 21 male) showing mild to moderate OSA were treated with Thornton Adjustable Positioners (TAP-T) modified with an intraoral sensor to objectively assess WT. Prior to (T0) and after 12 months of treatment (T1) cephalometric X-rays and intraoral scans (IOS) were obtained. IOS were superimposed by using iterative closest point algorithm to analyze dental changes within specific subregions in relation to individual WT. X-rays were taken to assess potential skeletal changes. Linear mixed-effects modelling (LMM) and Spearman's Rho were utilized for statistical analyses.

resultsThe present cohort showed a mean nocturnal WT of 5.52 h (± 1.75 h). Scan superimposition revealed minor dental side effects in all regions, with a greater percentage of adverse effects in the mandible. Along with labial displacement of lower and oral movement of upper incisors, we also found elongations and transverse widening of posterior teeth. WT showed significant influence on the magnitude of dental side effects, whereas Spearman's Rho revealed correlations of specific dental side effects with craniofacial morphology.

conclusionsDental adverse effects increase with treatment duration necessitating early detection. Greater susceptibility might appear in hyperdivergent craniofacial phenotypes, as well as more antero-positioned, horizontally oriented, prognathic mandibles. CLINICAL RELEVANCE: It is well known that strict case selection and careful MAD titration reduce the risk of dental side effects. However, monitoring of WT enables reliable observation of adherence to treatment instructions, such as reduction of application time or intermittent use, to avoid severe occlusal changes.

Indexed as

Mandibular AdvancementSleep Apnea, ObstructiveAdultCephalometryCross-Sectional StudiesFemaleHumansMaleMiddle AgedPatient ComplianceTime FactorsTreatment OutcomeCephalometryDental side effectsIntraoral sensorMandibular advancement deviceObjective wearing timeObstructive sleep apnea

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.