Accuracy Assessment of a Wrist-Worn Oscillometric Blood Pressure Device Applied to the Upper Arm in Children.
Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background Accurate blood pressure (BP) measurement in children is essential for detecting pediatric hypertension, yet validation evidence for wrist-worn oscillometric devices in this population is sparse. The nonstandard application of a wrist BP device to the upper arm, a clinically plausible scenario when cuff size is compatible with a child's arm circumference, has not been previously evaluated. This study aimed to evaluate the accuracy and validation of a wrist-worn oscillometric BP device applied to the upper arm in children aged 3-8.5 years using brachial auscultatory mercury sphygmomanometry as the reference standard. Methodology This prospective, cross-sectional validation study enrolled 100 children (58 males; mean age = 4.9 ± 1.5 years) in a tertiary care hospital. A wrist-worn oscillometric device was applied to the upper arm and compared with brachial auscultatory mercury sphygmomanometry using the International Organization for Standardization (ISO) 81060-2:2018. A same-arm sequential protocol was used, yielding 300 paired comparisons. Accuracy was assessed using ISO Criteria 1 and 2, the British Hypertension Society (BHS) grading, and Bland-Altman analysis. Additionally, proportional bias regression and subgroup analyses were performed. Results The device met both ISO criteria for systolic BP (SBP; mean error = -4.62 ± 6.02 mmHg) and diastolic BP (DBP; -2.70 ± 5.19 mmHg). BHS grading was Grade A for DBP and Grade B for SBP. Bland-Altman 95% limits of agreement were -16.41 to +7.17 mmHg (SBP) and -12.88 to +7.48 mmHg (DBP). Significant proportional bias was observed for SBP (r = 0.370, p < 0.001) and DBP (r = 0.153, p = 0.008) with increasing underestimation at higher BP values. No sex differences were identified; a statistically significant but small age group difference was observed for DBP only. Conclusions This wrist-worn device applied to the upper arm met ISO validation requirements in 3-8.5-year-old children, and achieved BHS Grade A for DBP and Grade B for SBP. This device may be used as a screening tool in children of the tested age range, with confirmatory brachial auscultation recommended for elevated readings. The predominantly normotensive BP distribution in this cohort limits generalization of performance to hypertensive pediatric populations
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.