ArticleUltrasonics2026
Hadamard-encoded synthetic beamforming for high frame rate acoustoelectric current source imaging.
Article in Ultrasonics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Acoustoelectric (AE) imaging can potentially image the current source density (CSD) in biological systems using ultrasound with high spatial and temporal resolution. However, existing approaches are limited by poor signal-to-noise ratio (SNR) and low frame rate, as conventional focused-beam scanning requires many scan lines to cover a large field of view (FOV). Here, we present spatial encoding using Hadamard synthetic beamforming (HSB) for ultrafast AE imaging. HSB was implemented using 16 transmit events for each image frame. While this number of transmissions severely restricts the FOV in conventional focused-beam scanning, the same number of HSB transmissions sufficiently samples the aperture, enabling reconstructions limited only by the transducer geometry. We validate this approach using a 1.5D transducer array operating in real time at a center frequency of 0.6 MHz to image the CSD of single and multiple dipole current sources varying at 200 Hz in a bio-mimicking phantom at a frame rate of 500 Hz, demonstrating the potential for ultrafast AE imaging. Measurements demonstrate an expected ∼ 5 dB improvement in SNR compared to conventional focused-beam scanning after pressure equalization. The spatial resolution of HSB was comparable to that of the focused ultrasound beam, with fewer waveform artifacts observed at the same frame rate. Finally, imaging distributed current sources at various depths further demonstrated improved image quality using dynamic beamforming with HSB compared with conventional beam scanning at a fixed focal depth. These results demonstrate that HSB provides a practical and robust solution for ultrafast AE imaging of bioelectric currents.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.