ArticleTranslational vision science & technology2026

Air-Coupled Ultrasonic Optical Coherence Elastography Reveals Protocol-Dependent Corneal Stiffening in Epi-On and Epi-Off Riboflavin Crosslinking.

Fernando Zvietcovich, Alejandra Varea-Bejar, Vlada Pleshcheva, Andrea Curatolo, Judith S Birkenfeld, Susana Marcos

Abstract read
In one paragraph

Article in Translational vision science & technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fernando ZvietcovichDepartment of Engineering, Pontificia Universidad Catolica del Peru, Lima, Peru.
Alejandra Varea-Bejar"Daza de Valdes" Institute of Optics, Spanish National Research Council, Madrid, Spain.
Vlada PleshchevaDepartment of Engineering, Pontificia Universidad Catolica del Peru, Lima, Peru.
Andrea Curatolo"Daza de Valdes" Institute of Optics, Spanish National Research Council, Madrid, Spain.
Judith S Birkenfeld"Daza de Valdes" Institute of Optics, Spanish National Research Council, Madrid, Spain.
Susana Marcos"Daza de Valdes" Institute of Optics, Spanish National Research Council, Madrid, Spain.

Funding

VISUAL SCIENCE RESEARCH CTR SUPPORTP30EY001319 · NEI · UNIVERSITY OF ROCHESTER · PI MICHELE RUCCI · 1985 to 2026
$17.5M
NEI NIH HHS P30 EY001319Wellcome Trust
6 · The paper itself

Abstract

Purpose: To evaluate the biomechanical impact of corneal crosslinking (CXL) when combining three different ultraviolet A (UV-A) riboflavin (RB) photosensitizers and protocols (Dresden protocol [DP] and accelerated protocol [AP]) using air-coupled ultrasonic optical coherence elastography in ex vivo rabbit corneas. Methods: An air-coupled ultrasound excitation optical coherence elastography system was used to excite the corneal apex and generate Lamb wave propagation along 16 corneal cross-sectional meridians. Measurements were conducted on ex vivo rabbit eyes (n = 45) during three treatment phases: Virgin, after 30 minutes of RB soaking, and after UV-A irradiation. The protocols used include the DP (3 mW/cm2, 30 minutes) and two accelerated protocols (AP-1: 9 mW/cm2, 10 minutes; and AP-2: 30 mW/cm2, 3 minutes). Each protocol was tested with three photosensitizers: epithelium-on (TE), and epithelium-off with hyperosmolar (M) and hypo-osmolar solutions (D). Lamb wave speed and average corneal thickness were calculated for each meridian to estimate meridian-dependent corneal shear modulus. Differences were statistically analyzed using linear mixed-effects regression. Results: The DP-D produced the strongest significant corneal stiffness increase (480.5 kPa; P < 0.001) during the UV irradiation phase, and the most pronounced corneal thinning (186 µm; P < 0.001). DP-TE achieved the next strongest stiffening (309.5 kPa) during UV irradiation, with no significant thickness change. All other protocol-photosensitizer combinations did not achieve significant corneal stiffening except for AP-1-D and AP-2-D during the RB soaking phase. Conclusions: Accelerated protocols did not produce significant corneal stiffening for any RB photosensitizer except when using dextran-based D. DP-D and DP-TE produced the greatest balance between shear modulus increase and corneal thickness decrease, suggesting DP-TE as a potential compromise between biomechanical impact, corneal integrity, and faster postoperative recovery. Translational Relevance: This work quantified the impact of clinically used crosslinking photosensitizers and protocols on corneal stiffening using an air-coupled ultrasound excitation optical coherence elastography, which holds promise for clinical assessments in patients.

Indexed as

CorneaCross-Linking ReagentsElasticity Imaging TechniquesPhotosensitizing AgentsRiboflavinTomography, Optical CoherenceAirAnimalsBiomechanical PhenomenaCorneal Cross-LinkingElasticityRabbitsUltraviolet RaysCross-Linking ReagentsPhotosensitizing AgentsRiboflavin