Evidence map›Paper›PMID 42428180›Full record

ArticleCureus2026

Stable Lord Madreporic Femoral Stem 32 Years After Revision Total Hip Arthroplasty: A Case Report.

José Rodrigues, João C Mendes, João Bessa, Pedro Farinha, Maria Parreira, Daniela Isidoro, António Mendonça, Fernando Judas

Abstract readCase Reports
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

José RodriguesOrthopedics and Traumatology, Coimbra Local Health Unit, Coimbra, PRT.
João C MendesOrthopedics and Traumatology, Coimbra Local Health Unit, Coimbra, PRT.
João BessaOrthopedics and Traumatology, Coimbra Local Health Unit, Coimbra, PRT.
Pedro FarinhaOrthopedics and Traumatology, Coimbra Local Health Unit, Coimbra, PRT.
Maria ParreiraOrthopedics and Traumatology, Coimbra Local Health Unit, Coimbra, PRT.
Daniela IsidoroOrthopedics and Traumatology, Unidade Local de Saúde de Coimbra, Coimbra, PRT.
António MendonçaOrthopedics and Traumatology, Coimbra Local Health Unit, Coimbra, PRT.
Fernando JudasOrthopedics and Traumatology, Coimbra Local Health Unit, Coimbra, PRT.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Lord total hip prosthesis was discontinued because of high rates of failure of the threaded acetabular component and marked proximal femoral bone atrophy related to stress shielding. We report an exceptionally long-term follow-up of a Lord femoral stem that remains stable 32 years after implantation. In 1994, a 37-year-old tailor underwent left revision total hip arthroplasty (THA) using the Lord system. Fifteen years later, in 2009, he presented in our orthopedic department with pain and substantial functional impairment. Imaging demonstrated aseptic loosening of the Lord acetabular cup with massive bone loss, and revision arthroplasty was performed. Periprosthetic bone loss was reconstructed with 120 cc of impacted cryopreserved morselized cancellous allograft, followed by implantation of a Burch-Schneider (Zimmer Biomet, IN, USA) anti-protrusio cage. The Lord femoral stem showed excellent osseointegration and mechanical stability and was therefore retained. An attempt to exchange the femoral head was unsuccessful due to cold welding at the Morse taper. In 2014, five years after the Lord acetabular revision, radiographs demonstrated fracture of the distal flange of the acetabular cage with lateralization of the implant. However, the patient remained asymptomatic and maintained satisfactory joint function, using a 2 cm shoe lift and a cane. A conservative watchful-waiting strategy was adopted. In 2026, at the 32-year follow-up, the Lord femoral stem continued to demonstrate clinical and radiographic stability, with no subsidence or progressive radiolucent lines besides secondary acetabular reconstruction challenges. To our knowledge, this represents one of the longest documented follow-up periods for a stable Lord femoral stem in the literature.

Indexed as

cold weldinglong-term outcomelord femoral stemlord total hip prosthesisrevision hip arthroplasty

Identifiers

PMID42428180
PMCPMC13348778

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.