Evidence map›Paper›PMID 42426290›Full record

ArticleDiscover mental health2026

Parkinson's disease focused multimodal wearable vision based gait monitoring system with real time feedback to support mobility and caregiver well-being.

Anusha M U, Uma Rani K, Puneeth N, Kishor M, Nemichandra S C, Deepak Dharrao, Anupkumar M Bongale

Abstract read
PubMed Publisher
In one paragraph

Article in Discover mental health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Anusha M UDepartment of Electronics and Instrumentation, Sri Jayachamarajendra College of Engineering, JSS Science and Technology University, Mysuru, Karnataka, 570006, India.
Uma Rani KDepartment of Electronics and Instrumentation, Sri Jayachamarajendra College of Engineering, JSS Science and Technology University, Mysuru, Karnataka, 570006, India.
Puneeth NDepartment of Artificial Intelligence and Robotics, School of Engineering, Dayananda Sagar University, Devarkaggalahalli, Harohalli, Bengaluru South, Karnataka, India.
Kishor MDepartment of Psychiatry, JSS Medical College and Hospital, JSS Academy of Higher Education and Research, Mysuru, Karnataka, 570015, India.
Nemichandra S CDepartment of Neurology, JSS Medical College and Hospital, JSS Academy of Higher Education and Research, Mysuru, Karnataka, 570015, India.
Deepak DharraoDepartment of Computer Science and Engineering, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune, Maharashtra, 412115, India.
Anupkumar M BongaleDepartment of Artificial Intelligence and Machine Learning, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune, Maharashtra, 412115, India. anupkumar.bongale@sitpune.edu.in.ORCID https://orcid.org/0000-0002-5897-0283

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A chronic and progressive neurological disorder, Parkinson's disease (PD) has a significant influence on patients and their caregivers. Motor symptoms such as postural instability, tremors, and gait dysfunction lead to increased dependency, high caregiver vigilance, and chronic psychological distress in terms of stress, anxiety, and reduced quality of life. Caregivers of patients with PD experience chronic emotional and cognitive distress due to the uncertainty and unpredictability of motor symptoms in daily life, which are not effectively managed by traditional episodic clinical evaluations. To address this gap, we propose a multimodal gait analysis and feedback system that objectively evaluates motor dysfunction and provides remote supervision capabilities that may potentially support caregiver monitoring and reduce the need for constant physical vigilance. The system combines wearable sensors IMUs and flex sensors with a vision-based pose estimation algorithm to continuously monitor tremors and gait dysfunction in a home setting. When deviation exceeds clinically defined thresholds, real-time haptic, visual, and auditory feedback is provided, and wireless data synchronization enables remote monitoring by caregivers and clinicians. In a pilot trial conducted on six patients with PD (Hoehn and Yahr stages 2-3) and one healthy control, the gait classification system achieved a mean accuracy of 88.0% across PD participants and an average feedback response time of approximately 210 ms. The alignment of sensor-derived outputs with standardised clinical scales (MDS-UPDRS Part III) supports the clinical interpretability of this system in a home monitoring context. This sensor-integrated monitoring platform is designed to reduce caregiver monitoring burden and may, in future studies with formal caregiver outcome measures, demonstrate benefit to caregiver mental health and quality of life.

Indexed as

Caregiver supportMultimodal gait monitoringParkinson’s diseaseReal-time feedbackRemote patient monitoringWearable sensors

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.