Evidence map›Paper›PMID 42423318›Full record

ArticleJACC. Case reports2026

Early Degeneration of a Next-Generation Mitral Bioprosthesis in the Tricuspid Position Treated With Valve-in-Valve.

Silvia Corona, Sebastián Mrad, Reda Ibrahim, Blandine Mondésert, Marco Julien, Louis-Philippe David, Patrick Garceau, Denis Bouchard, Stephanie Tan, Ralph Stephan von Bardeleben and 1 more

Abstract readCase Reports
In one paragraph

Article in JACC. Case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Silvia CoronaStructural Heart Valve Center and Cardiac Surgery Department, Montreal Heart Institute, Montreal, Canada. Electronic address: silviacoro89@gmail.com.
Sebastián MradStructural Heart Valve Center and Interventional Cardiology Department, Montreal Heart Institute, Montreal, Canada.
Reda IbrahimStructural Heart Valve Center and Interventional Cardiology Department, Montreal Heart Institute, Montreal, Canada.
Blandine MondésertElectrophysiology Department, Montreal Heart Institute, Montreal, Canada.
Marco JulienAnesthesia Department, Montreal Heart Institute, Montreal, Canada.
Louis-Philippe DavidEchocardiography Department, Montreal Heart Institute, Montreal, Canada.
Patrick GarceauEchocardiography Department, Montreal Heart Institute, Montreal, Canada.
Denis BouchardStructural Heart Valve Center and Cardiac Surgery Department, Montreal Heart Institute, Montreal, Canada.
Stephanie TanRadiology Department, Montreal Heart Institute, Montreal, Canada.
Ralph Stephan von BardelebenStructural Heart Valve Center and Interventional Cardiology Department, Montreal Heart Institute, Montreal, Canada.
Walid Ben AliStructural Heart Valve Center and Cardiac Surgery Department, Montreal Heart Institute, Montreal, Canada. Electronic address: dr.walidbenali@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBioprosthetic tricuspid valve replacement is increasingly performed, but long-term durability data are limited. The Edwards Mitris Resilia valve, designed for the mitral position, has been used off-label in the tricuspid position, with scarce evidence of outcomes. CASE SUMMARY: We report 2 patients who developed early (<2-year) structural valve degeneration of the Mitris Resilia bioprosthesis in the tricuspid position. Both presented with symptomatic severe intraprosthetic tricuspid regurgitation. Given the prohibitive surgical risk of redo sternotomy, we opted for valve-in-valve (ViV) transcatheter tricuspid valve replacement (TTVR) using the Edwards Sapien 3 Ultra Resilia transcatheter heart valve. Both procedures were successful, with no residual regurgitation or paravalvular leak. DISCUSSION: To our knowledge, this is the first reported series of early Mitris Resilia structural valve degeneration in the tricuspid position. The cases highlight potential concerns about the durability of bioprostheses in the tricuspid position, especially in congenital heart disease or redo settings. Valve-in-valve tricuspid valve replacement with balloon-expandable transcatheter valves proved to be feasible, safe, and effective, preventing high-risk surgical reoperation. Early intervention is crucial to avoid irreversible right ventricular dysfunction.

Indexed as

reoperationSVDtricuspid regurgitationtricuspid valveTTVRViV

Identifiers

PMID42423318
PMCPMC13350662

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.