Evidence map›Paper›PMID 42422481›Full record

ArticleFrontiers in pain research (Lausanne, Switzerland)2026

Feasibility and reliability of pressure algometry for mechanical nociceptive threshold quantification in lambs in a field environment.

Charlotte Helen Johnston, Danila Marini, Stefan T Musolino, Daniel T Barratt, Mark R Hutchinson

Abstract read
In one paragraph

Article in Frontiers in pain research (Lausanne, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Charlotte Helen JohnstonSchool of Biomedicine, Faculty of Health and Medical Sciences, University of Adelaide, Australia, Adelaide, SA, Australia.
Danila MariniDavies Livestock Research Centre, University of Adelaide, Roseworthy, SA, Australia.
Stefan T MusolinoSchool of Biomedicine, Faculty of Health and Medical Sciences, University of Adelaide, Australia, Adelaide, SA, Australia.
Daniel T BarrattSchool of Biomedicine, Faculty of Health and Medical Sciences, University of Adelaide, Australia, Adelaide, SA, Australia.
Mark R HutchinsonSchool of Biomedicine, Faculty of Health and Medical Sciences, University of Adelaide, Australia, Adelaide, SA, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To validate a modified algometer method for assessing mechanical nociceptive threshold (MNT) in lambs before and after husbandry procedures (marking) under field conditions by testing the precision, intra-operator reliability and agreement, and minimal detectable change (MDC). Animals: Forty-six randomly allocated Merino lambs: 6 control (sham handled), 13 hot knife tail docked, 13 rubber ring tail docked, 7 hot knife tail docked and rubber ring castrated, and 7 rubber ring tail docked and castrated. Methods: MNT (mean triplicate measurements at each replicate) was assessed at the tail base, using three replicate measurements before, and three hours after marking to assess precision, reliability, agreement, and MDC. A single operator performed all testing, with lambs restrained by one of three handlers (randomly) for each replicate. Within-animal/-occasion (pre- or post-marking) relative and absolute precision were evaluated using the coefficient of variation (CV) and a combination of standard deviation (SD) and dispersion modelling, respectively. Agreement was assessed using Bland-Altman plots, and linear mixed effects regression was used to determine the intra-class correlation coefficient (ICC) for intra-operator reliability, and any systematic effects of replicate order or handler. MDC was calculated from the standard error of measurement. Responsiveness to marking was analyzed by comparing MNT change from pre- to post-marking using linear mixed effects regression. Results: The overall median MNT was 3.07 kgf (IQR = 2.00-3.84, range = 1.23-5.00). Greater body weight was associated with significantly higher absolute imprecision ( Conclusions: Modified algometer MNT measurement in lambs around the time of marking was feasible with sufficient precision and responsiveness to demonstrate a reduction in nociceptive threshold following husbandry procedures.

Indexed as

agreementalgometerintra-operator reliabilitymechanical nociceptive thresholdprecisionsheeptail docking

Identifiers

PMID42422481
PMCPMC13341597

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.