ArticlePlastic and reconstructive surgery. Global open2026
Detection of Microvascular Failure Using Bioimpedance and Sensor-derived Clinical Indicators: A Preliminary Study.
Article in Plastic and reconstructive surgery. Global open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Early detection of flap failure is critical for successful salvage surgery outcomes. Delays in diagnosis can lead to additional surgical intervention, tissue necrosis, or even flap loss. Current monitoring methods rely heavily on intermittent clinical evaluations, which are subjective and time-consuming and may miss early signs of failure. A continuous, objective monitoring system could significantly improve detection accuracy and response times. This study explores a multisensory strategy to identify early physiological changes associated with flap failure. Methods: Using a rat hindlimb model, flap failure was simulated via femoral vein or artery clamping (n = 5 per group). Physiological responses-including temperature, skin color, and bioimpedance-were recorded continuously for 2 hours postclamping with sensors. Statistical significance was set at a Results: Clear physiological trends emerged in failure groups. We preliminarily validated a multisensor approach for free flap monitoring in a rat model using temperature, bioimpedance, and color sensing. Each modality provided distinct and complementary insights into perfusion changes: color sensing detected changes fastest but was more variable, temperature changes were moderate and potentially influenced by external heating, and bioimpedance showed the most consistent trends over time, highlighting the value of a combined sensing strategy for reliable tissue viability assessment. Conclusions: This multisensory approach demonstrates strong potential for early, noninvasive flap failure detection through continuous monitoring of temperature, color, and bioimpedance. These findings support further development of real-time sensing systems to enhance surgical outcomes and patient safety in flap-based procedures.
Identifiers
What OpenQuestion holds
Registered trials