Evidence map›Paper›PMID 42422141›Full record

ArticleJournal of medical physics

An Analysis of Quality Assurance for Intensity-modulated Radiation Therapy and Volumetric Modulated Arc Therapy Treatment Plans Using Two Dosimetric Methods: The arcCHECK System and EPIbeam Based Dosimetric Approach.

Ajay Katake, Lalit Kumar, Balbir Singh, Amit Sharma, Deepak Basandrai

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ajay KatakeDepartment of Physics, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Phagwara, Punjab, India.
Lalit KumarDepartment of Radiation Oncology, Max Superspeciality Hospital, Saket, New Delhi, India.
Balbir SinghDepartment of Radiation Oncology, SLBSGMC and H, Nerchowk, Mandi, Himachal Pradesh, India.
Amit SharmaDepartment of Radiation Oncology, N M Virani Wockhardt Hospital, Rajkot, Gujrat, India.
Deepak BasandraiDepartment of Physics, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Phagwara, Punjab, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: The current study is to assess and compare the performance of an electronic portal imaging device (EPID)-based dosimetry system electronic portal imaging beam (EPIbeam) and a three-dimensional (3D) diode array system (ArcCHECK) using various gamma criteria (3%/3 mm, 2%/2 mm, 3%/2 mm and 1%/1 mm) in verifying intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans at different anatomical sites. Materials and Methods: A total of 100 clinical IMRT and VMAT treatment plans covering head and neck (HN), thoracic and pelvic sites were considered for patient specific quality assurance (PSQA). All the plans were calculated with the Monaco TPS (v6.1.4.0) and were treated with an Elekta Infinity linear accelerator with 6 MV photon beams. EPID-based portal dosimetry (EPIbeam, DosiSoft) and ArcCHECK (Sun Nuclear Corporation) were utilized to carry out PSQA. All plans were analyzed using global gamma with 10% dose threshold and 95% pass-rate. Results: A 3%/3 mm, EPID showed almost perfect pass rates (99.48%-100%) in HN, Thoracic, and Pelvic regions, and ArcCHECK was also close behind (97%-100%). EPID and ArcCHECK performed with a high level of accuracy (97.82-100 and 88.5%-98.8%, respectively) under stricter 2%/2 mm criteria. Using 3%/2 mm gamma criteria, EPID demonstrates higher pass rates (98.6%-100%), and ArcCHECK had also increased (93.2%-99.8%). In the most stringent 1%/1 mm, the performance of EPID declined moderately (77.28%-98.73%), and ArcCHECK had the lowest pass rates (61.6%-91.4%). In general, EPID exhibited better and more reproducible dose delivery accuracy in all conditions. The differences between the quality assurance (QA) systems were statistically significant ( Conclusion: The PSQA systems EPID-based and ArcCHECK-based are valuable dosimetric verification of IMRT and VMAT. Their sensitivity and accuracy are emphasized by gamma analysis on several criteria. The EPID system offers Logistical advantage in clinical workflow, whereas ArcCHECK provides 3D dose verification. Both modalities are viable in clinical QA protocols.

Indexed as

ArcCHECKDosiSoftelectronic portal imaging beamelectronic portal imaging devicepatient specific quality assurance

Identifiers

PMID42422141
PMCPMC13345026

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.