Evidence map›Paper›PMID 42420979›Full record

ArticleBMC medical informatics and decision making2026

Stress distribution in three-unit implant-supported prostheses with different abutment designs: a finite element analysis.

Ismail Furkan Guney, Busra Tosun

Abstract read
In one paragraph

Article in BMC medical informatics and decision making, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ismail Furkan GuneyDepartment of Prosthodontics, Faculty of Dentistry, Bolu Abant Izzet Baysal University, Bolu, Turkey.ORCID http://orcid.org/0000-0001-9835-9289
Busra TosunDepartment of Prosthodontics, Faculty of Dentistry, Bolu Abant Izzet Baysal University, Bolu, Turkey. dtbusra86@hotmail.com.ORCID http://orcid.org/0000-0003-3145-4454

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImplant-supported prostheses are widely used in posterior mandibular restorations, where biomechanical factors play a critical role in long-term performance. Abutment design may influence stress distribution within implant-supported systems, potentially affecting both prosthetic components and surrounding bone. This study aimed to evaluate stress distribution in three-unit implant-supported prostheses with different abutment designs using three-dimensional finite element analysis.

methodsA three-dimensional finite element model of the posterior mandible with two implants (4.1 mm diameter, 10 mm length) placed in the first premolar and first molar regions was constructed. Three abutment designs (multi-unit, octa, and variobase) supporting monolithic zirconia restorations were analyzed. Vertical (150 N) forces were applied perpendicular to the occlusal surfaces, and oblique (200 N at 45°) forces were applied in the buccolingual direction. Stress distribution in implants, abutments, screws, restorations, and surrounding bone was evaluated.

resultsStress distribution varied according to abutment design and loading condition. Variobase abutments showed higher stress concentrations in implants under both loading conditions, while octa abutments exhibited higher stress values in screws and restorations. Multi-unit abutments demonstrated relatively lower stress values in screws and restorations compared to other designs. Oblique loading produced higher stress levels than vertical loading across all components. Bone stress values increased under oblique loading conditions.

conclusionsWithin the limitations of this finite element analysis, abutment design influenced stress distribution in implant-supported prostheses, and loading direction affected stress magnitude. These findings provide biomechanical insight into the behavior of different abutment designs in posterior implant-supported restorations.

Indexed as

Dental AbutmentsDental Implant-Abutment DesignDental ImplantsDental Prosthesis, Implant-SupportedDental Stress AnalysisFinite Element AnalysisHumansMandibleStress, MechanicalDental ImplantsDental implantFinite element analysisMulti-unit abutmentStress distributionTi-base abutment

Identifiers

PMID42420979
PMCPMC13632230

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.