Evidence map›Paper›PMID 42418011›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2026

Interface stability of intramedullary nail locking configurations under combined axial and torsional loading.

Hollensteiner Marianne, Winkler Martin, Gerber Claus, Borowsky Anja, Augat Peter

Abstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hollensteiner MarianneInstitute for Biomechanics, BG Unfallklinik Murnau gGmbH, Prof. Küntscher Str. 8, 82418, Murnau, Germany. marianne.hollensteiner@bgu-murnau.de.
Winkler MartinInstitute for Biomechanics, BG Unfallklinik Murnau gGmbH, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Gerber ClausStryker Trauma GmbH, Schönkirchen/Kiel, Germany.
Borowsky AnjaStryker Trauma GmbH, Schönkirchen/Kiel, Germany.
Augat PeterInstitute for Biomechanics, BG Unfallklinik Murnau gGmbH, Prof. Küntscher Str. 8, 82418, Murnau, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The biomechanical performance of intramedullary nails in metaphyseal regions strongly depends on distal locking configuration. This study aimed to evaluate screw-bone interface stability under combined axial and torsional cyclic loading for different distal locking configurations of intramedullary nails, focusing on the effects of screw number, spatial distribution, interscrew distance, and multiplanar versus coplanar fixation using a standardized synthetic bone model. Six distal locking configurations (n = 5 per group) were tested under stepwise cyclic axial compression, superimposed with a constant torsional moment (± 2 Nm, 2 Hz). Primary endpoints were cycles to failure, cycles to 1 mm axial displacement, and cycles to 0.5° rotation. All constructs failed by progressive screw cut-through within the synthetic bone. The three-screw multiplanar configuration exhibited the highest endurance (≈ 36,000 cycles to failure) and lowest micromotion (≈ 34,000 cycles to 1 mm displacement), significantly outperforming the two-screw configurations overall (p = 0.002). Increasing interscrew distance from 10 mm to 34 mm improved migration resistance by approximately 25%, whereas the short 10 mm spacing led to premature failure. Blocked and free-hand configurations showed comparable behavior to the standard setup, indicating no added benefit from toggle elimination alone. Locking configuration decisively influences the performance of the implant-bone interface in intramedullary nail constructs. Multiplanar distal locking with adequate screw spacing enhances interface stability and may provide biomechanical advantages for metaphyseal fixation to reduce screw migration and early loss of fixation.

Indexed as

Bone NailsBone ScrewsFracture Fixation, IntramedullaryBiomechanical PhenomenaHumansMaterials TestingTorsion, MechanicalAngle-stable fixationIntramedullary nailingLocking configurationScrew-bone interfaceSynthetic bone model

Identifiers

PMID42418011
PMCPMC13346156

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.