Evidence map›Paper›PMID 42415277›Full record

ArticleJournal of applied clinical medical physics2026

Real-time motion tracking of a gold implant in water by Cherenkov lights.

Keita Okazaki, Eric Brost, Gopishankar Natanasabapathi, Yoichi Watanabe

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Keita OkazakiDepartment of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota, USA.ORCID https://orcid.org/0009-0005-5238-8021
Eric BrostDepartment of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA.
Gopishankar NatanasabapathiDepartment of Radiation Oncology, Dr. B. R. A. Institute Rotary Cancer Hospital, All India Institute of Medical Sciences, New Delhi, Delhi, India.ORCID https://orcid.org/0000-0002-5623-3343
Yoichi WatanabeDepartment of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota, USA.ORCID https://orcid.org/0000-0001-8086-6442

Funding

All India Institute of Medical Sciences (AIIMS), IndiaICMR-DHR
6 · The paper itself

Abstract

backgroundThe intra-fraction motion of tumors during radiation therapy can be monitored using imaging systems based on X-ray imaging (e.g., kV/MV radiography or CBCT) or magnetic resonance imaging (MRI). However, these techniques have limitations, including additional ionizing radiation dose and the need for complex, expensive equipment. Hence, a non-invasive, lower-cost motion-tracking approach that does not add radiation would be beneficial for routine clinical applications. PURPOSE: To study the feasibility of tracking the dynamic motion of a small gold marker in water by using Cherenkov photons produced by MV photon beams, through Monte Carlo simulations and experiments.

methodsThe GAMOS Monte Carlo code, which includes an optical simulation module, was used to calculate the deposited dose and Cherenkov-light yield in a water phantom. Phase-space files for 6, 10, 15, and 10 MV flattening filter-free (FFF) beams served as photon sources. The simulation setup consisted of a 20 × 20 × 20 cm

resultsMonte Carlo simulations showed that Cherenkov light yield throughout the phantom closely correlated with the PDD for all beam energies. The Cherenkov light yield upstream of the gold implant increased by 6.12%, 7.16%, 9.11%, and 7.01% compared to the Cherenkov light yield without the gold implant for 6, 10 FFF, 10, and 15 MV beams, respectively. Experiments confirmed that the beam-facing side of the gold implant appeared brighter than the opposite side, indicating enhanced backscattered electron production. Cherenkov-based positional measurements of the periodically moving implant showed close agreement with bright-room references. For static beams, accuracy across motion patterns was < 0.70 mm with repeatability < 0.2 mm. For the VMAT plan, the accuracies were < 0.50 mm (Arc A) and < 0.70 mm (Arc B).

conclusionThe Cherenkov-light yield was strongly correlated with the deposited dose and showed a notable enhancement around the gold implant. Cherenkov light imaging successfully tracked the dynamic motion of a gold implant in water under high-dose rate conditions, demonstrating its potential for real-time fiducial tracking in radiation therapy without additional radiation exposure.

Indexed as

GoldMonte Carlo MethodPhantoms, ImagingProstheses and ImplantsRadiotherapy Planning, Computer-AssistedWaterHumansImage Processing, Computer-AssistedMotionMotion CaptureMovementPhotonsRadiotherapy DosageRadiotherapy, Intensity-ModulatedGoldWaterCherenkov lightgold implantMonte CarloMotion‐trackingradiotherapy

Identifiers

PMID42415277
PMCPMC13341642

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.