Evidence map›Paper›PMID 42412096›Full record

ArticleUlusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES2026

Intermediate screw placement improves initial radiographic alignment but not clinical outcomes following long-segment fixation for thoracolumbar fractures.

Onur Süer, Bünyamin Kılıçlı, Selahaddin Aydemir, Anıl Murat Öztürk, Ömer Akçalı

Abstract readComparative Study
In one paragraph

Article in Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Onur SüerDepartment of Orthopaedics and Traumatology, Izmir City Hospital, Izmir-Türkiye.
Bünyamin KılıçlıDepartment of Orthopaedics and Traumatology, Faculty of Medicine, Ege University, Izmir-Türkiye.
Selahaddin AydemirDepartment of Orthopaedics and Traumatology, Kastamonu Research and Training Hospital, Kastamonu-Türkiye.
Anıl Murat ÖztürkDepartment of Orthopaedics and Traumatology, Faculty of Medicine, Ege University, Izmir-Türkiye.
Ömer AkçalıDepartment of Orthopaedics and Traumatology, Faculty of Medicine, Dokuz Eylul University, Izmir-Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe role of intermediate screws in long-segment posterior fixation for thoracolumbar fractures remains controversial. This study aimed to evaluate their effectiveness in improving alignment, maintaining correction, and reducing complications.

methodsThis retrospective comparative study included 91 patients with unstable thoracolumbar burst fractures (T11-L2) treated between 2014 and 2022. Patients were divided into two cohorts: Group A (n=61), who underwent long-segment fixation with intermediate screws inserted at the fracture level, and Group B (n=30), who received conventional fixation. Radiological outcomes, including vertebral compression angle (VCA) and anterior/posterior vertebral body height (ABH/PBH), intraoperative parameters (operative time and fluoroscopy use), clinical pain scores assessed using the Visual Analog Scale (VAS), and complications were analyzed. Statistical comparisons were performed using t-tests and chi-square tests.

resultsBoth groups demonstrated significant postoperative improvements in VCA and vertebral body height (p<0.0001). Group A achieved superior early correction of VCA compared with Group B (4.78°±3.47 vs. 6.82°±4.02, p=0.014), and this difference remained significant at the two-year follow-up (5.67°±3.08 vs. 8.59°±3.76, p=0.0005). Although correction loss was lower in Group A (1.22°±1.13 vs. 1.95°±2.12, p=0.122), the difference was not statistically significant. Group A required longer operative times (160.25±19.4 vs. 150.17±26.9 minutes, p=0.044) and greater fluoroscopy exposure (26.38±2.3 vs. 20.00±2.13, p<0.001). No significant differences were observed between groups in preoperative or follow-up VAS scores (p>0.05).

conclusionPlacement of intermediate screws in long-segment constructs was associated with significantly enhanced restoration and maintenance of radiographic alignment in patients with thoracolumbar fractures, although it required longer operative time and increased fluoroscopy use. Clinical pain outcomes were comparable between groups. These findings suggest that intermediate screw placement may provide biomechanical and radiographic advantages in selected cases where optimal anatomical restoration is prioritized. This technique was associated with improved initial and long-term radiographic alignment, at the cost of longer operative time and greater radiation exposure, but did not improve pain outcomes. However, the non-random assignment of patients according to surgeon preference should be considered when interpreting these results.

Indexed as

Bone ScrewsFracture Fixation, InternalLumbar VertebraeSpinal FracturesThoracic VertebraeAdultFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment Outcome

Identifiers

PMID42412096
PMCPMC13401173

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.