Evidence map›Paper›PMID 42410572›Full record

ArticleBMC oral health2026

Biomechanical effects of different carbon fiber-reinforced polyetheretherketone dental implants materials in edentulous maxilla: A 3D finite element study.

Shengnan Qin, Mingyu Bai, Jie Zhang, Yuzhao Cheng, Xingxing Xue, Yang Wu

Abstract read
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shengnan QinThe Stomatology Department of Shanxi Provincial People's Hospital, Shanxi Medical University, Taiyuan, 030001, China.
Mingyu BaiShanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Shanxi Medical University School and Hospital of Stomatology, Taiyuan, 030001, China.
Jie ZhangThe Stomatology Department of Shanxi Provincial People's Hospital, Shanxi Medical University, Taiyuan, 030001, China.
Yuzhao ChengThe Stomatology Department of Shanxi Provincial People's Hospital, Shanxi Medical University, Taiyuan, 030001, China.
Xingxing XueXinzhou Dental Clinic, Hamony Long Limited Company, Xinzhou, 034000, China.
Yang WuThe Stomatology Department of Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Taiyuan, 030032, China. 495294388@qq.com.

Funding

Natural Science Foundation of Shanxi Province 202503021212367
6 · The paper itself

Abstract

objectiveThis finite element analysis study aimed to compare the biomechanical performance of implants made from polyetheretherketone (PEEK), 30% short carbon fiber-reinforced PEEK (30% SCFR-PEEK), 60% continuous carbon fiber-reinforced PEEK (60% CCFR-PEEK), and titanium in a full-arch fixed implant restoration for the edentulous maxilla.

methodsA three-dimensional finite element model of an edentulous maxilla was constructed from Cone-Beam Computed Tomography (CBCT) data. The bone was modeled with a 2 mm cortical layer surrounding a cancellous core. Four implants supporting a full-arch prosthesis were simulated. Implants materials were assigned properties from literature (PEEK: 4.1 GPa; 30% SCFR-PEEK: 18 GPa; 60% CCFR-PEEK: 150 GPa; titanium: 110 GPa). Three occlusal loading conditions (centric, lateral, protrusive) were applied. The maximum von Mises stress values and stress distribution in the implants, cortical bone, and cancellous bone was analyzed.

resultsImplant stress was highest in 60% CCFR-PEEK, followed by titanium, 30% SCFR-PEEK, and PEEK. Cortical bone stress was lowest around stiff implants (60% CCFR-PEEK, titanium) and highest around PEEK and 30% SCFR-PEEK. The 30% SCFR-PEEK group showed the smallest implant-bone stress gradient and the most uniform stress distribution.

conclusionThe 30% SCFR-PEEK implant exhibited superior biomechanical compatibility for maxillary complete-arch rehabilitation. Its intermediate stiffness promoted physiological stress transfer to peri-implant bone.

Indexed as

CarbonCarbon FiberDental ImplantsDental MaterialsJaw, EdentulousKetonesMaxillaPolyethylene GlycolsBenzophenonesBiomechanical PhenomenaCone-Beam Computed TomographyDental Prosthesis DesignDental Prosthesis, Implant-SupportedDental Stress AnalysisFinite Element AnalysisHumansBenzophenonesCarbonCarbon FiberDental ImplantsDental MaterialsKetonesPolyether CompoundspolyetheretherketonePolyethylene GlycolsPolymersTitaniumCarbon fiber reinforcedDental implantsFinite element analysisPolyetheretherketone

Identifiers

PMID42410572
PMCPMC13621708

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.