Evidence map›Paper›PMID 42410371›Full record

ArticleBMC cancer2026

The impact of orthogonal image-guided frequency on positioning error correction and dose in postoperative radiotherapy for breast cancer.

Fangfen Dong, Shanting He, Bing Wu, Jiaming Li, Zhixin Wang, Yong Yang, Benhua Xu, Yifa Zhao, Xiaobo Li

Abstract read
In one paragraph

Article in BMC cancer, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Fangfen Dong *Department of Radiation Oncology, Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematological and Breast Malignancies), Fujian Medical University Union Hospital, Fuzhou, 350001, China.
Shanting He *Department of Radiation Oncology, Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematological and Breast Malignancies), Fujian Medical University Union Hospital, Fuzhou, 350001, China.
Bing WuSchool of Medical Imaging, Fujian Medical University, Fuzhou, 350004, China.
Jiaming LiSchool of Medical Imaging, Fujian Medical University, Fuzhou, 350004, China.
Zhixin WangSchool of Medical Imaging, Fujian Medical University, Fuzhou, 350004, China.
Yong YangDepartment of Radiation Oncology, Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematological and Breast Malignancies), Fujian Medical University Union Hospital, Fuzhou, 350001, China.
Benhua XuDepartment of Radiation Oncology, Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematological and Breast Malignancies), Fujian Medical University Union Hospital, Fuzhou, 350001, China.
Yifa ZhaoZhangpu County Hospital, Zhangpu, 363299, China. 13960082972@163.com.
Xiaobo LiDepartment of Radiation Oncology, Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematological and Breast Malignancies), Fujian Medical University Union Hospital, Fuzhou, 350001, China. lixiaobo2004@126.com.

Funding

Fujian Medical University Sailing Fund General Project 2022QH1029Fujian Province Health Youth Research Project 2022QNA018
6 · The paper itself

Abstract

background and purposeThe incidence and mortality of breast cancer are increasing year by year. Image-guided radiotherapy (IGRT) after breast cancer surgery is one of the important ways of comprehensive treatment of breast cancer, but the frequency of IGRT and additional radiation damage are one of the key problems of clinical attention. To investigate the impact of different orthogonal image-guided frequencies on positioning error correction, plan target volume (PTV) margin expansion, and dose distribution in postoperative radiotherapy for breast cancer patients, providing a reference for the optimal orthogonal image-guided frequency in clinical practice for post-surgical breast cancer radiotherapy patients. MATERIALS AND

methodsFrom January 2021 to January 2022, 61 patients undergoing postoperative intensity-modulated radiation therapy (IMRT) for breast cancer at Fujian Medical University Union Hospital were selected. Prior to each radiation session, initial setup errors were measured as the control group (Group A) using real-time orthogonal images aligned with digitally reconstructed radiographs (DRR). Automatic couch adjustments were then performed based on alignment results within specified error tolerances to determine residual setup errors. Data collected were categorized into experimental Groups B1 to B5 based on different verification frequencies (every 1 to 5 days). Statistical analysis was conducted on the grouped data to calculate PTV expansion margins under different error conditions and assess their impact on dose.

resultsIn the study involving 61 patients, a total of 915 datasets were collected. The initial setup errors in three translational directions were (3.57 ± 3.48) mm, (2.76 ± 2.60) mm, and (2.65 ± 2.28) mm, respectively. With increasing verification frequency, residual setup errors gradually decreased. Under daily verification frequency, residual errors were (1.65 ± 0.90) mm, (1.60 ± 0.94) mm, and (1.56 ± 0.90) mm in the three translational directions. Pairwise comparisons between control and experimental groups indicated that differences were statistically significant except between B3 Vs B4, and B4 Vs B5. Based on setup error calculations under different verification frequencies, the reference PTV expansion margins decreased with increasing frequency. Specifically, under daily verification, the calculated PTV expansion reference values reduced from initial uncorrected setup errors of 6.53 mm, 5.07 mm, and 4.01 mm to 1.26 mm, 1.41 mm, and 1.29 mm, respectively. The differences between verification frequencies of every 3 days, 4 days, and 5 days were minimal. Finally, virtual error plans were designed in the treatment planning system based on average errors for each group of patients. Deviations in target area doses were statistically significant compared to the original plan across different imaging frequencies.

conclusionDaily image-guided setup verification (including correction) effectively reduces setup errors in postoperative breast cancer IGRT. Variations exist in the efficacy of error correction and its impact on PTV expansion and dose among different verification frequencies. Higher frequencies exhibit more significant error correction effects, necessitating smaller PTV expansions. At the same time, daily image guidance can reduce the dose of the heart and left lung. Further follow-up studies are required to track the impact of these deviations on dose and clinical efficacy.

Indexed as

Breast NeoplasmsPatient PositioningRadiotherapy, Image-GuidedRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedRadiotherapy Setup ErrorsAdultFemaleHumansMiddle AgedRadiotherapy, AdjuvantRadiotherapy DosageBreast cancerImage-guided frequencyIntensity-modulated radiotherapySetup error

Identifiers

PMID42410371
PMCPMC13632276

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.