Image sharpening improves the visibility of reference points on low-dose lateral cephalometric radiographs: a phantom study.
Article in Dento maxillo facial radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
This phantom study aimed to determine whether a novel non-artificial intelligence image-sharpening approach improves the visibility of reference points on low-dose lateral cephalometric radiographs. Lateral cephalometric radiographs were obtained using an adult human bone phantom at 100% of the routine dose. Low-dose imaging was performed using 60%, 40%, and 20% of the routine dose. Each low-dose image underwent a 2-level image-sharpening process using the Medical Image Enhancer software. Six reviewers evaluated the visibility of the 5 reference points in the first and second sets of sharpened and 100% radiation-dose images. Using Scheffé's method of paired comparisons, odds ratios (ORs) were reported as relative values for a standard cephalometric radiograph (100% radiation dose) to compare the visibility of reference points among imaging conditions. For the first set of mildly sharpened 60%-dose images, the ORs for the 4 reference points were >1.0, Point A (OR 1.12, P = .83), Nasion (OR 2.26, P = .11), posterior nasal spine (OR 2.35, P = .1), and incisal edge of the maxillary central incisor (OR 1.35, P = .53), indicating visibility comparable to or better than the 100%-dose images. For the second set of markedly sharpened images, rated visibility was significantly higher for all reference points at 60% and 40% doses and for several reference points at 20% dose. Image-sharpening algorithms improved the visibility of reference points on low-dose phantom radiographs, suggesting their technical feasibility as a post-acquisition approach for dose-reduced cephalometric imaging.