Evidence map›Paper›PMID 42403747›Full record

ArticleCureus2026

Flexible Bronchoscopic Retrieval of an Aspirated Toy Whistle Using a Modified 4 Fr Fogarty Balloon Technique.

Eldhos Jacob, Srishankar Bairy, Jason G Dsouza, Carishma S, Basil B Mathews

Abstract readCase Reports
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Eldhos JacobRespiratory Medicine, Father Muller Medical College Hospital, Mangaluru, IND.
Srishankar BairyRespiratory Medicine, Father Muller Medical College Hospital, Mangaluru, IND.
Jason G DsouzaPaediatrics, Father Muller Medical College Hospital, Mangaluru, IND.
Carishma SRespiratory Medicine, Father Muller Medical College Hospital, Mangaluru, IND.
Basil B MathewsRespiratory Medicine, Father Muller Medical College Hospital, Mangaluru, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Foreign body aspiration in children is an important cause of airway morbidity and may present with persistent cough, delayed diagnosis, atelectasis, and granulation tissue formation. Smooth hollow plastic foreign bodies may be particularly difficult to retrieve because standard forceps often fail to achieve a secure grip, and balloon-assisted techniques may be limited by repeated slippage. We report the case of a seven-year-old boy who presented with a persistent cough for 15 days following aspiration of a toy whistle. He was referred to our center after an unsuccessful retrieval attempt at another hospital in South India. Chest radiography at our institution demonstrated left lung volume loss with compensatory contralateral hyperinflation, while computed tomography performed at the referring center demonstrated an endobronchial foreign body in the left main bronchus with lingular atelectasis. Flexible bronchoscopy was selected as a staged minimally invasive approach with rigid bronchoscopy backup immediately available. The procedure was performed under general anesthesia through a laryngeal mask airway using a Fujifilm EB-710P slim bronchoscope (Fujifilm, Tokyo, Japan) with a 2.2 mm working channel. During the initial bronchoscopy session, multiple whistle fragments were removed using alligator and rat-tooth forceps; however, a retained hollow cylindrical component could not be extracted because granulation tissue and retained secretions limited visualization. Nebulized budesonide was administered between procedures as part of institutional clinical practice to reduce airway inflammation and improve visualization, and repeat bronchoscopy was performed the following day. During the second session, a 4 Fr Fogarty balloon catheter was advanced distal to the retained component. Balloon inflation with air repeatedly failed because of slippage within the smooth lumen, whereas inflation with 0.5 mL saline achieved improved anchorage and enabled successful extraction. Follow-up imaging demonstrated complete lung re-expansion. This case highlights the importance of individualized procedural planning and a staged bronchoscopic approach in technically difficult pediatric airway foreign bodies. Saline inflation of a Fogarty balloon catheter may represent a practical troubleshooting modification in selected hollow airway foreign bodies when conventional retrieval techniques fail.

Indexed as

atelectasisflexible bronchoscopyfogarty catheterforeign body aspirationpediatric bronchoscopy

Identifiers

PMID42403747
PMCPMC13333181

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.