Evidence map›Paper›PMID 42403266›Full record

Trial reportCatheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions2026

A Randomized Controlled Trial Comparing the TruSteer and FXD Double Curve Delivery Systems for Left Atrial Appendage Occlusion With the Watchman FLX Pro Device-The GUIDE-LAAO Study.

Philippe Taieb, Marco Frazzetto, Pedro Soares Teixeira, Steven J Filby

Abstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Philippe TaiebHarrington Heart & Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.ORCID https://orcid.org/0000-0003-4287-3371
Marco FrazzettoHarrington Heart & Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.ORCID https://orcid.org/0000-0002-6543-7567
Pedro Soares TeixeiraHarrington Heart & Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.
Steven J FilbyHarrington Heart & Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.ORCID https://orcid.org/0000-0001-8364-1732

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDeflectable delivery systems have been introduced to enhance coaxial alignment and procedural efficacy during left atrial appendage occlusion (LAAO), yet randomized comparisons with conventional fixed-curve systems are lacking.

aimsThe GUIDE-LAAO trial evaluated whether the TruSteer deflectable delivery system is non-inferior to the FXD Double Curve (FXD DC) delivery system for procedural success in patients undergoing LAAO with the Watchman FLX Pro device.

methodsIn this prospective, randomized, all-comers trial, 50 patients with non-valvular atrial fibrillation undergoing LAAO were assigned 1:1 to TruSteer (n = 25) or FXD DC (n = 25). The primary endpoint was procedural success, defined as successful device implantation without major procedural or periprocedural complications. Secondary endpoints included technical success, device success, procedural efficiency, and safety outcomes.

resultsProcedural success occurred in 100% of TruSteer-treated patients and 84% of FXD DC-treated patients (risk difference 16%; 95% confidence interval -6.9% to 34.7%), meeting criteria for non-inferiority; superiority was not demonstrated (p = 0.11). Technical and device success were 100% with TruSteer and 92% with FXD DC. Procedural time (34.6 ± 7.1 vs. 36.5 ± 13.0 min), fluoroscopy time (22.3 ± 4.4 vs. 22.1 ± 7.2 min), and contrast volume (34.5 ± 12.1 vs. 36.8 ± 13.5 mL) were similar. Periprocedural complications occurred in 4% and 16%, respectively, with no deaths or strokes.

conclusionsIn this first randomized comparison of LAAO delivery systems, TruSteer was non-inferior to a standard fixed-curve system, with comparable efficiency and safety in an unselected population. These findings provide randomized evidence supporting deflectable delivery technology in contemporary LAAO practice and inform future studies in anatomically complex subsets.

Indexed as

Atrial AppendageAtrial FibrillationCardiac CatheterizationCardiac CathetersLeft Atrial Appendage ClosureAgedAged, 80 and overEchocardiography, TransesophagealEquipment DesignFemaleHumansMaleMiddle AgedProspective StudiesRisk FactorsStrokeatrial fibrillationdelivery systemleft atrial appendage occlusionstroke preventionWATCHMAN

Identifiers

PMID42403266
PMCPMC13532461

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.