Evidence map›Paper›PMID 42403208›Full record

ArticleUltrasonography (Seoul, Korea)2026

A new single-sagittal-plane deep learning approach for continuous bladder volume monitoring: a feasibility study.

Junhwan Kwon, Ilseob Song, Sangeun Park, Jongsoo Lee, Yangmo Yoo

Abstract read
In one paragraph

Article in Ultrasonography (Seoul, Korea), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Junhwan KwonEdgecare Inc., Seoul, Korea.
Ilseob SongEdgecare Inc., Seoul, Korea.
Sangeun ParkEdgecare Inc., Seoul, Korea.
Jongsoo LeeDepartment of Urology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Yangmo YooEdgecare Inc., Seoul, Korea.

Funding

Ministry of Food and Drug Safety RS-2023-00243901Ministry of Health and WelfareMinistry of Science and ICTMinistry of Trade, Industry and EnergySeverance Hospital Research Fund for Clinical excellence C-2024-0020
6 · The paper itself

Abstract

purposeConventional ultrasound-based bladder volumetry multiplies three orthogonal diameters and applies a heuristic shape coefficient. This approach requires near-simultaneous transverse and sagittal imaging and is vulnerable to interplane misregistration and coefficient-dependent bias. This study evaluated whether a single sagittal B-mode image can provide accurate, patient-specific bladder volume estimation by leveraging sagittal morphology, perivesical echotexture, and latent image features associated with overall bladder geometry.

methodsIn this Institutional Review Board-approved, single-center study, participants were scanned in the supine position, and bladder volume was referenced to immediate Foley catheter drainage. Segmentation masks were independently annotated by two sonographers and adjudicated by a urologist. Maximum sagittal length was extracted using OpenCV and included as an auxiliary scalar input. A single-stage deep learning model was developed that receives one sagittal B-mode image and its expert-annotated segmentation mask as input. The model used a lightweight convolutional neural network backbone with integrated self-attention to capture global echotextural cues. Performance on a held-out test set (n=53) was assessed using linear regression, Bland-Altman analysis, mean absolute error, and mean absolute percentage error.

resultsThe model demonstrated a strong correlation with catheter-derived volumes (R²=0.87). Bland-Altman analysis showed a mean bias of -3.96±48.44 mL, with limits of agreement from -98.90 to +90.98 mL. Stratified error analysis showed a mean absolute error of 14.15 mL for volumes of 0-100 mL and a mean absolute percentage error of 16.64% for volumes ≥100 mL. Attention maps emphasized the bladder wall and perivesical soft tissues, suggesting reliance on contextual echotexture.

conclusionA deep learning framework using a single sagittal plane estimated bladder volume with accuracy approaching that of two-plane techniques while simplifying image acquisition and eliminating reliance on fixed shape coefficients.

Indexed as

Bladder volumeContinuous monitoringDeep learningPoint-of-care ultrasoundSingle-plane imaging

Identifiers

PMID42403208
PMCPMC13554572

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.