Evidence map›Paper›PMID 42402571›Full record

ArticleBMC musculoskeletal disorders2026

Mechanical effects of valgus osteotomy angle and re-fixation strategies on re-fixation of the femoral neck fracture: a finite element analysis.

Hongyu Lin, Fukang Zhu, Taiyou Wang, Heling Tan, Shuquan Guo, Bo Qiao

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hongyu Lin *Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, China.
Fukang Zhu *Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, China.
Taiyou WangDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, China.
Heling TanDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, China.
Shuquan GuoDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, China. gsq1974@126.com.
Bo QiaoDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, China. qiaobo1985@163.com.

Funding

Chongqing Municipal Science and Technology Bureau No.cstc2020jscx-sbqwX0010
6 · The paper itself

Abstract

aimsThis study examined the biomechanical outcomes of osteotomy angles and the internal fixation devices for re-fixation of the femoral neck fracture.

methodsThe finite element model of femoral neck fracture was initially fixed with three cannulated screws, followed by 10° and 20° valgus osteotomy. The models were re-fixed using sliding hip screw (DHS) + anti-rotation screw (AS) or DHS + medial buttress plate (MBP). Physiological loads were applied to all models.

resultWith 10° and 20° valgus osteotomy, the interfragmentary shear stress, sliding distance, and gap decreased, the compressive stress increased. With a further 10° osteotomy angle, the interfragmentary sliding distance in DHS + AS group decreased by 38.4%, and the interfragmentary compressive stress in DHS + MBP group increased by 20.9%. The interfragmentary shear stress and gap showed changes of no more than 10%. For the sliding distance, gap, and shear stress, DHS + AS is slightly superior to DHS + MBP at both osteotomy angle. The Von Mises stress of the internal fixation device for DHS + AS is 22.61% higher than that for DHS + MBP at a 20° osteotomy angle.

conclusionBoth 10° and 20° osteotomy angles enhance the mechanical strength and stability at the fracture site, which may offer potential options for the clinical selection of valgus osteotomy angles. DHS + AS exhibits better mechanical stability but may carry a higher risk of internal fixation failure. Patients treated with DHS + AS may require more cautious postoperative weight-bearing; however, this should be validated in clinical studies. Meanwhile, with the development of bone tissue engineering, the material strength of internal fixation devices may improve, reducing the risk of internal fixation device failure.

Indexed as

Femoral Neck FracturesFinite Element AnalysisFracture Fixation, InternalOsteotomyBiomechanical PhenomenaBone PlatesBone ScrewsHumansReoperationStress, MechanicalFemoral neck fractureFinite element analysisInternal fixationRe-fixationValgus osteotomy

Identifiers

PMID42402571
PMCPMC13613701

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.