ArticleEnvironmental health and preventive medicine2026
High-throughput, low volume d-ROMs and BAP assays: 384-well plate method for large-scale studies.
Article in Environmental health and preventive medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe d-ROMs and BAP serum tests are promising markers of oxidative balance in research settings. Conventional assay systems require 30 µL of serum and approximately 10 minutes to analyze a single sample. Although these systems have the advantages of calibration-free operation and the flexibility to perform individual tests at any time, their limited throughput and relatively high cost restrict their use in large-scale studies.
methodsTo address this issue, we developed a small-scale, semi-automated measurement system incorporating a pipetting robot and a 384-well plate. The system requires only 5.0 µL of serum sample and can process up to 144 samples simultaneously for both d-ROMs and BAP assays (a total of 288 measurements).
resultsBased on nonlinearity testing, 450 nm was selected as the optimal wavelength. To maintain linearity across various sample types, including turbid serum, d-ROMs required incubation at 4 °C for one week, and BAP required centrifugation to remove precipitates. Intra- and inter-assay, as well as inter-day, coefficients of variation ranged from 1% to 9% for d-ROMs and 2% to 17% for BAP. Inter-operator variations were <9%. Lipemic serum showed abnormally low BAP values using the conventional method but normal values using our method. In non-turbid samples, the current and conventional methods showed high agreement. Deming regression analysis of log
conclusionsWe have developed a high-throughput, cost-effective in-house assay system for large-scale studies. This system provides accurate measurements of oxidative stress markers even in turbid samples, facilitating robust evidence-based research on oxidative stress and health.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.