Evidence map›Paper›PMID 42402416›Full record

ArticleEnvironmental health and preventive medicine2026

High-throughput, low volume d-ROMs and BAP assays: 384-well plate method for large-scale studies.

Goki Yamada, Sudarma Bogahawaththa, Yuichiro Nishida, Mikako Horita, Kazuhiro Kawamoto, Yasuyuki Maeda, Mikiko Tokiya, Megumi Hara, Tadayuki Tsujita, Akiko Matsumoto

Abstract read
In one paragraph

Article in Environmental health and preventive medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Goki YamadaDepartment of Preventive Medicine, Faculty of Medicine, Saga University.
Sudarma BogahawaththaDepartment of Social and Environmental Medicine, Faculty of Medicine, Saga University.
Yuichiro NishidaDepartment of Preventive Medicine, Faculty of Medicine, Saga University.
Mikako HoritaDepartment of Preventive Medicine, Faculty of Medicine, Saga University.
Kazuhiro KawamotoDepartment of Social and Environmental Medicine, Faculty of Medicine, Saga University.
Yasuyuki MaedaDepartment of Social and Environmental Medicine, Faculty of Medicine, Saga University.
Mikiko TokiyaDepartment of Social and Environmental Medicine, Faculty of Medicine, Saga University.
Megumi HaraDepartment of Preventive Medicine, Faculty of Medicine, Saga University.
Tadayuki TsujitaThe United Graduate School of Agricultural Sciences, Kagoshima University.
Akiko MatsumotoDepartment of Social and Environmental Medicine, Faculty of Medicine, Saga University.ORCID http://orcid.org/0000-0002-8445-4071

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe d-ROMs and BAP serum tests are promising markers of oxidative balance in research settings. Conventional assay systems require 30 µL of serum and approximately 10 minutes to analyze a single sample. Although these systems have the advantages of calibration-free operation and the flexibility to perform individual tests at any time, their limited throughput and relatively high cost restrict their use in large-scale studies.

methodsTo address this issue, we developed a small-scale, semi-automated measurement system incorporating a pipetting robot and a 384-well plate. The system requires only 5.0 µL of serum sample and can process up to 144 samples simultaneously for both d-ROMs and BAP assays (a total of 288 measurements).

resultsBased on nonlinearity testing, 450 nm was selected as the optimal wavelength. To maintain linearity across various sample types, including turbid serum, d-ROMs required incubation at 4 °C for one week, and BAP required centrifugation to remove precipitates. Intra- and inter-assay, as well as inter-day, coefficients of variation ranged from 1% to 9% for d-ROMs and 2% to 17% for BAP. Inter-operator variations were <9%. Lipemic serum showed abnormally low BAP values using the conventional method but normal values using our method. In non-turbid samples, the current and conventional methods showed high agreement. Deming regression analysis of log

conclusionsWe have developed a high-throughput, cost-effective in-house assay system for large-scale studies. This system provides accurate measurements of oxidative stress markers even in turbid samples, facilitating robust evidence-based research on oxidative stress and health.

Indexed as

High-Throughput Screening AssaysOxidative StressBiomarkersHumansReproducibility of ResultsBiomarkersBAPd-ROMsHigh-throughputOxidative balancePipetting robotValidation

Identifiers

PMID42402416
PMCPMC13366183

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.