Evidence map›Paper›PMID 42402075›Full record

ArticleDiscover nano2026

Statistical analysis of Casson hybrid nanofluid flow over a stenotic artery.

Gunisetty Ramasekhar, Mohammed Almakki, A Divya

Abstract read
In one paragraph

Article in Discover nano, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Gunisetty RamasekharDepartment of Mathematics, Rajeev Gandhi Memorial College of Engineering and Technology (Autonomous), Nandyal, Andhra Pradesh, 518501, India.
Mohammed AlmakkiDepartment of Engineering, Amity University Dubai, P.O. Box 345019, Dubai International Academic City, United Arab Emirates.
A DivyaSchool of Technology, The Apollo University, Chittoor, Andhra Pradesh, 517127, India. divya_abbaireddy@apollouniversity.edu.in.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The flow of blood through stenotic arteries is considered one of the most significant areas of investigation in the world of mathematical fluid mechanics. This significance arises from the topic's application to the field of biomedicine. Within an arterial system of blood that has been stenosed, the goal of this research initiative is to investigate the effect that nanoparticles have on the characteristics that define the human circulatory system. The current investigation analyzes blood flow behavior in a controlled, permeable artery employing the Casson hybrid nanofluid model and, additionally, gold, Cu, and silver nanoparticles. The current study examines the investigation of magnetohydrodynamics (MHD) Casson hybrid nanofluid Darcy-Forchheimer flow (DFF) over a stenotic artery with a heat source/sink. By transforming the partial differential equations (PDEs) into ordinary differential equations (ODEs) by utilizing suitable similarity variables. After that, the mathematical solution of these equations used the BVP4c method in the MATLAB solver and analysis for skin and Nusselt number table values for hybrid nanofluid cases. The statistical analysis is used to solve for different physical factors. During a study in which values of both variables are subject to essentially unknown oversights, the task is utilizing statistical techniques to discover the best possible linear equations. In this concept, two different hybrid nanomaterials are used for analyzing heat transfer characteristics. According to these graphical results, the present model concludes that case-2 has better performance than case-1. Rising values of the magnetic parameter improve heat transfer owing to Joule heating impacts and control flow via the Lorentz force, which in turn affects the distribution of shear stresses close to the artery wall. The current work highlights the role of nanoparticles and magnetic fields in enhancing flexibility near arteries' surfaces. This work has substantial repercussions for the treatment of cancer and the treatments that are used to avoid cardiovascular disease, as it suggests that improved heat transfer and shear stress distribution can enhance the effectiveness of therapies targeting tumor cells and improve blood flow in cardiovascular interventions.

Indexed as

Bvp4c methodCasson fluidHeat source/sinkHybrid nanofluidMHDPorous mediumStenotic artery

Identifiers

PMID42402075
PMCPMC13333575

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.