Pulse pressure versus continuous flow monitoring for fluid responsiveness prediction during passive leg raising: a prospective diagnostic accuracy study.
Article in BMC anesthesiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAccurate prediction of fluid responsiveness is essential in managing circulatory shock. While passive leg raising (PLR) is recommended in international guidelines, its diagnostic validity depends critically on the monitoring modality used to detect hemodynamic responses. In resource-limited settings, manual blood pressure measurement remains the predominant available technology, yet its adequacy for PLR interpretation has not been rigorously evaluated in an adequately powered study with an independent reference standard.
objectiveTo compare the diagnostic accuracy of manual pulse pressure change (ΔPP%) versus continuous flow monitoring (USCOM-1 A, ΔSV%) for predicting fluid responsiveness during PLR in intensive care unit (ICU) patients with undifferentiated shock, using echocardiographic cardiac output assessment as an independent reference standard.
methodsProspective single-center diagnostic accuracy study enrolling consecutive ICU patients with undifferentiated shock at Sina Educational and Medical Center, Tehran, Iran (2020-2021). A standardized PLR protocol was performed with simultaneous blinded measurements by three independent operators: manual blood pressure via calibrated sphygmomanometer, continuous flow monitoring via USCOM-1 A, and echocardiographic velocity-time integral (VTI) measurement as the reference standard. Fluid responsiveness was defined as ≥ 15% cardiac output increase following 500 mL crystalloid challenge. Primary outcome was area under the receiver operating characteristic curve (AUC). The study followed Standards for Reporting Diagnostic Accuracy Studies (STARD) 2015 guidelines (Ethics approval: IR.SBMU.PHARMACY.REC.1399.316).
resultsOf 124 patients analyzed (mean age 58.1 ± 19.8 years, 65.3% female), 58 (46.8%) were fluid responders. Continuous flow monitoring demonstrated acceptable diagnostic accuracy (AUC 0.712, 95% confidence interval [CI] 0.622-0.802; sensitivity 81.0%; specificity 61.8%; negative predictive value [NPV] 79.2%). Manual pulse pressure demonstrated significantly inferior discrimination (AUC 0.601, 95%CI 0.502-0.700; DeLong test P = 0.029) with critically low sensitivity (32.8%) and clinically inadequate NPV (57.8%). Bootstrap-corrected performance estimates confirmed the robustness of findings (USCOM AUC 0.708; Manual pulse pressure [PP] AUC 0.596). Mean pulse pressure remained essentially unchanged during PLR (+ 0.4 ± 4.6 mmHg, P = 0.287) despite significant proportional increases in both systolic (+ 3.7%) and diastolic (+ 5.6%) pressures, and despite echocardiographically confirmed stroke volume augmentation (left ventricular outflow tract [LVOT] VTI + 15.9%). The correlation between ΔPP% and ΔSV% was weak (r = 0.39, R²=0.15). Baseline method comparison between USCOM-derived and echocardiography-derived cardiac output showed low paired bias, although the percentage error exceeded the conventional interchangeability threshold, supporting interpretation of USCOM as a directional flow-monitoring index rather than a fully interchangeable substitute for echocardiography.
conclusionsIn this single-center study, manual pulse pressure demonstrated insufficient sensitivity (32.8%) and inadequate NPV (57.8%) for reliable fluid responsiveness prediction during PLR. Our findings suggest it should be interpreted with considerable caution, particularly when the test result is negative. Continuous flow monitoring provides superior and clinically acceptable diagnostic accuracy when available, although USCOM should be interpreted as a directional flow-monitoring index rather than a fully interchangeable substitute for echocardiographic cardiac output measurement. The proportional pressure increase phenomenon provides a mechanistic explanation for this diagnostic limitation. These findings require multicenter validation before definitive practice recommendations can be issued.