Evidence map›Paper›PMID 42399594›Full record

ArticleMedical & biological engineering & computing2026

Anti-aliasing-enhanced WaveUNet for clinically reliable 12-lead ECG reconstruction from limited 3-lead input.

Mine Onat, Hazret Tekin, Yılmaz Kaya

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mine OnatFaculty of Engineering and Architecture, Batman University, Batman, Türkiye, 72100, Turkey.
Hazret TekinVocational School of Technical Sciences, Şırnak University, Şırnak, Türkiye, Turkey. hazrettekin@sirnak.edu.tr.ORCID http://orcid.org/0000-0002-9379-721X
Yılmaz KayaFaculty of Engineering and Architecture, Batman University, Batman, Türkiye, 72100, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Standard 12-lead electrocardiography (ECG) remains the clinical gold standard for diagnosing cardiac disorders, particularly myocardial infarction (MI). However, electrode-count constraints in portable and wearable ECG systems make simultaneous acquisition of all 12 leads impractical, thereby challenging the preservation of diagnostic fidelity. This study aims to reconstruct physiologically coherent and clinically meaningful 12-lead ECGs from a limited 3-lead input configuration. To this end, we developed a WaveUNet-based encoder-decoder architecture and systematically extended it with alternative anti-aliasing and resampling strategies, including BlurPool, AAPool, AAStride, NearestConv, and PixelShuffle. The models were trained and evaluated on the PTB-XL dataset using ten different three-lead input combinations. Reconstruction quality was assessed using signal-level metrics, including RMSE, MAE, R², and PRD. In addition, the diagnostic utility of the reconstructed 12-lead signals was quantitatively examined through MI versus non-MI classification. The experimental results demonstrate that the baseline WaveUNet provides strong and stable reconstruction performance, while anti-aliasing-based variants yield additional improvements, particularly for input combinations containing precordial leads. The highest signal-level accuracy was achieved with the I-II-V2 and I-II-V3 combinations, reaching R² values of approximately 0.86-0.87. Lead-wise analyses further revealed that inclusion of at least one chest lead is critical for accurate reconstruction of precordial outputs. In diagnostic evaluation, the AAStride variant delivered the most balanced MI classification performance, achieving 84.3% accuracy, an F1-score of 0.720, and an ROC-AUC of 0.908. Overall, the findings indicate that anti-aliased WaveUNet-based 3-to-12 lead ECG reconstruction can provide clinically meaningful morphological and diagnostic consistency for low-electrode wearable and portable ECG systems.

Indexed as

ElectrocardiographySignal Processing, Computer-AssistedAlgorithmsHumansMyocardial Infarction12-lead electrocardiographyAnti-aliasingECG reconstructionMyocardial infarction detectionWaveUNet

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.