Intrasystem Repeatability of S-Detect for Breast Ultrasound Classification With Identical Static Images: Single-Center Retrospective Repeatability Study.

Liang Yongping, Ping Zhou, Yang Wang, Nan Zhang, Qing Zhou, Xinghao Zhang, Haifeng Cai, Zhang Juan

Abstract read
In one paragraph

Article in JMIR medical informatics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Liang YongpingDepartment of Ultrasound, Tangshan People's Hospital, Tangshan, China.ORCID 0000-0003-1510-5991
Ping ZhouDepartment of Ultrasound, Third Xiangya Hospital, Changsha, China.ORCID 0009-0004-5035-7187
Yang WangDepartment of Ultrasound, Tangshan People's Hospital, Tangshan, China.ORCID 0009-0005-6210-4539
Nan ZhangDepartment of Breast Surgery, Tangshan People's Hospital, Shengli Road #65, Tangshan, 063000, China, 86 13393159122.ORCID 0009-0004-7708-3673
Qing ZhouDepartment of Breast Surgery, Tangshan People's Hospital, Shengli Road #65, Tangshan, 063000, China, 86 13393159122.ORCID 0009-0004-4109-4717
Xinghao ZhangDepartment of Ultrasound, Third Xiangya Hospital, Changsha, China.ORCID 0000-0002-3466-4628
Haifeng CaiDepartment of Breast Surgery, Tangshan People's Hospital, Shengli Road #65, Tangshan, 063000, China, 86 13393159122.ORCID 0009-0001-3062-3298
Zhang JuanDepartment of Breast Surgery, Tangshan People's Hospital, Shengli Road #65, Tangshan, 063000, China, 86 13393159122.ORCID 0000-0001-5089-723X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Computer-aided diagnostic systems such as S-Detect (Samsung Medison) are increasingly integrated into breast ultrasound workflows. Notwithstanding extensive past evaluation of S-Detect's diagnostic accuracy, its intrasystem repeatability at the software level with identical static images, a fundamental prerequisite for clinical reliability, has not been systematically investigated. Objective: This study aimed to evaluate the intrasystem repeatability of the S-Detect computer-aided diagnostic system in classifying breast nodules in identical static ultrasound images. Methods: This retrospective, registered, blinded repeatability study analyzed 398 breast nodules from 261 women (mean age 43.10, SD 12.57 years) who underwent surgery between February 2019 and March 2020 at a single institution. Identical stored static ultrasound images, acquired by a single experienced sonographer on 1 Samsung RS80A ultrasound system, were each analyzed twice using the same S-Detect workstation: immediately after acquisition (S-Detect 1) and again at least 4 weeks later under blinded conditions with manual cursor repositioning (S-Detect 2). Repeatability was assessed using concordance rate and Cohen κ. The diagnostic performance of each run was compared against surgical histopathology. Results: Of 398 nodules, 156 (39.2%) were initially classified as possibly benign, and 242 (60.8%) were initially classified as possibly malignant. On repeat analysis, 37.4% (149/398) and 62.6% (249/398) of the nodules were classified as possibly benign and malignant, respectively. A total of 4.5% (7/156) of the nodules initially classified as benign were reclassified as malignant, whereas no malignant-to-benign changes occurred. The overall concordance rate was 98.2% (391/398), with a Cohen κ of 0.95 (95% CI 0.94-0.99; P<.001). Diagnostic performance remained stable across runs (area under the curve=0.913 vs 0.902; P=0.702). Conclusions: Under controlled conditions with identical static images, S-Detect showed high intrasystem repeatability, underscoring strong software-level consistency, although its translation to real-world clinical reproducibility requires further validation.

Indexed as

BreastBreast NeoplasmsUltrasonography, MammaryAdultFemaleHumansMiddle AgedReproducibility of ResultsRetrospective Studiesbreast cancercomputer‑aided diagnosisrepeatabilityS‑Detectultrasonography

Identifiers

PMID42397885
PMCPMC13331062

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.