Evidence map›Paper›PMID 42397159›Full record

ArticleMagnetic resonance in medicine2026

Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging.

Jae-Youn Keum, Jang-Yeon Park

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Jae-Youn KeumDepartment of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea.ORCID https://orcid.org/0009-0000-6328-0300
Jang-Yeon ParkDepartment of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea.

Funding

National Research Foundation of Korea RS-2023-NR077284
6 · The paper itself

Abstract

purposeThis study aims to address the suppression of oscillation and ghosting appearing in RF-spoiled gradient-echo-based dynamic imaging, which is caused by the pseudo-steady state (PSS) of magnetization. THEORY AND

methodsWe extended the concept of the previous RF phase-cycle-adapted averaging method to RF-spoiled gradient-echo-based cine (or 2D line-scan) imaging by introducing an appropriate intertrial RF phase-cycle shift while maintaining flexibility in the number of phase-encoding lines. The proposed method was validated through theoretical analysis based on the PSS magnetization, 2D Bloch simulations, phantom and human brain imaging on a 3 T clinical scanner. Furthermore, its performance was evaluated using spectral analysis and tSNR maps.

resultsIn both phantom and human brain images, the proposed method effectively suppressed ghosting artifacts and oscillatory components at specific frequencies. Averaging over multiple trials, whose number is determined by the number of phase increment (ψ) rotations required for the PSS magnetization to return to its initial phase, fully eliminated the ghosts and oscillatory components, and even when the number of trials was reduced, it significantly mitigated them. The proposed method provided robust performance in both phantom and human brain images, with improved signal quality as shown in tSNR maps.

conclusionIn this work, we theoretically investigated the PSS behavior of magnetization in RF-spoiled gradient-echo-based cine imaging and demonstrated a method to effectively suppress oscillation and ghosting appearing in RF-spoiled gradient-echo-based cine images. This study is expected to provide a valuable tool for various applications of ultrahigh temporal resolution MRI, including fMRI, utilizing cine imaging.

Indexed as

BrainImage Processing, Computer-AssistedMagnetic Resonance ImagingMagnetic Resonance Imaging, CineAlgorithmsArtifactsComputer SimulationHumansImage EnhancementImage Interpretation, Computer-AssistedPhantoms, ImagingRadio WavesReproducibility of Results2D line‐scangradient‐echo‐based cine imagingpseudo‐steady stateRF phase‐cycle‐adapted averagingRF spoilingultrahigh temporal resolution

Identifiers

PMID42397159
PMCPMC13527254

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.