Evidence map›Paper›PMID 42395915›Full record

ArticleResearch and practice in thrombosis and haemostasis2026

Resolving the dilution paradox to improve the interpretation of extracellular vesicle biomarker studies.

Joyce Rops, Naomi C Buntsma, Aleksandra Gąsecka, Rienk Nieuwland, Aleksandra Rosiek, Yvo B W E M Roos, A Yaël Nossent, Nyika D Kruyt, Edwin van der Pol, Ceren Eyileten

Abstract read
In one paragraph

Article in Research and practice in thrombosis and haemostasis, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Measurement of extracellular vesicles using flow cytometry: friend or foe?Research and practice in thrombosis and haemostasis · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Joyce RopsLaboratory of Experimental Clinical Chemistry, Laboratory Specialized Diagnostics & Research, Department of Laboratory Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
Naomi C BuntsmaLaboratory of Experimental Clinical Chemistry, Laboratory Specialized Diagnostics & Research, Department of Laboratory Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
Aleksandra GąseckaLaboratory of Experimental Clinical Chemistry, Laboratory Specialized Diagnostics & Research, Department of Laboratory Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
Rienk NieuwlandLaboratory of Experimental Clinical Chemistry, Laboratory Specialized Diagnostics & Research, Department of Laboratory Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
Aleksandra RosiekDepartment of Child and Adolescent Psychiatry, Institute of Psychiatry and Neurology, Warsaw, Poland.
Yvo B W E M RoosAmsterdam Cardiovascular Sciences, Atherosclerosis and Ischemic Syndromes, Amsterdam, Netherlands.
A Yaël NossentDepartment of Nutrition, Exercise and Sports, University of Copenhagen, Copenhagen, Denmark.
Nyika D KruytDepartment of Neurology, Leiden University Medical Center, Leiden, Netherlands.
Edwin van der PolLaboratory of Experimental Clinical Chemistry, Laboratory Specialized Diagnostics & Research, Department of Laboratory Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
Ceren EyiletenDepartment of Experimental and Clinical Pharmacology, Centre for Preclinical Research and Technology (CePT), Medical University of Warsaw, Warsaw, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Concentrations of extracellular vesicles (EVs) and other particles are measured in plasma for biomarker exploration. A commonly used method, flow cytometry, requires plasma dilution to ensure single-particle detection. Since plasma EVs are outnumbered by variable concentrations of lipoproteins, dilution differs between the plasma samples. Dilution can result in misidentification of fluorescent background signals as labeled EVs. This phenomenon, called the dilution paradox, leads to overestimation of plasma EV concentrations, and likely impacts conclusions from earlier performed biomarker studies. Objectives: This study reevaluated earlier conclusions from our clinical biomarker studies Antiplatelet Therapy Effect on Extracellular Vesicles (AFFECT EV) and Circulating Nanotraces to Identify the Cause of Stroke (CINTICS), by taking the dilution paradox into account. Methods: We developed a model that quantifies the fluorescent background and estimates whether a flow cytometry measurement is dominated by fluorescent background, that is, if the measurement is unreliable. This model was applied to the original datasets of the AFFECT EV and CINTICS studies to identify and exclude unreliable measurements. We investigated whether exclusion of unreliable data affects the original conclusions. Results: Our model estimated that 47% (1156/2457) of the evaluated measurements are unreliable, and conclusions from both biomarker studies required adjustment. Conclusion: Our model improves reliability and reproducibility of EV concentration measurements using flow cytometry. We recommend to reanalyze earlier EV flow cytometry studies using our model and to use a fixed dilution factor in future EV flow cytometry studies to enable reliable EV concentration measurements.

Indexed as

Extracellular VesiclesFlow CytometryStrokeBiomarkersHumansIndicator Dilution TechniquesReproducibility of ResultsBiomarkersbiomarkersextracellular vesiclesflow cytometrymyocardial infarctionstroke

Identifiers

PMID42395915
PMCPMC13325907

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.