Evidence map›Paper›PMID 42393668›Full record

ArticleBMC oral health2026

Thermoforming time variability of PET-G and TPU aligner sheets across consecutive thermoforming cycles: an in vitro study.

Thi Bich Van Tran, Ngoc Anh Thu Pham, Thi Huong Loan Pham

Abstract read
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Thi Bich Van TranFaculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
Ngoc Anh Thu PhamFaculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
Thi Huong Loan PhamFaculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam. phamthuongloan@ump.edu.vn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThermoforming time is a critical parameter in the fabrication of thermoformed orthodontic aligners, as it influences polymer softening, material adaptation, and dimensional consistency. Manufacturer-recommended heating durations are typically based on standardized conditions and may not reflect the dynamic thermal behavior of thermoforming units during consecutive fabrication cycles. Empirical data quantifying heating-time variation and stabilization patterns remain limited.

methodsThis in vitro study evaluated heating-time variation across 20 consecutive thermoforming cycles in two commercially available thermoplastic aligner materials: a multilayer polyethylene terephthalate glycol/thermoplastic polyurethane composite (Zendura FLX) and a single-layer thermoplastic polyurethane sheet (Maxflex), both with a nominal thickness of 0.76 mm. Each material underwent ten independent experimental sessions (total n = 200 cycles per material) using a standardized pressure-forming unit under controlled environmental conditions (23 ± 1 °C; 50 ± 5% humidity). Heating was terminated at a predefined sag depth of 16 mm, determined using a laser-based measurement system. Linear mixed-effects models were used to assess cycle-dependent variation, and simple linear regression was applied to the pre-stabilization phase.

resultsHeating time progressively decreased across consecutive thermoforming cycles for both materials. Zendura FLX stabilized from cycle 6 onward, with a steady-state mean of 64.59 ± 3.58 s. Maxflex stabilized from cycle 12 onward, with a steady-state mean of 69.37 ± 1.12 s. During the transient phase, heating time decreased linearly by 8.66 s per cycle for Zendura FLX (R² = 0.78) and 4.17 s per cycle for Maxflex (R² = 0.97). Both transient and steady-state heating durations were significantly longer than Supplier-Recommended Thermoforming Times (p < 0.0001).

conclusionsHeating time during thermoforming decreased across consecutive cycles before reaching material-specific stabilization thresholds. For both materials, experimentally determined heating durations exceeded manufacturer-recommended times under controlled laboratory conditions, suggesting that thermoforming behavior may vary dynamically during repeated fabrication cycles.

Indexed as

Hot TemperatureOrthodontic Appliance DesignOrthodontic Appliances, RemovablePolyurethanesHumansIn Vitro TechniquesMaterials TestingPolyethylene GlycolsPolyethylene TerephthalatesTime FactorsPolyethylene Glycolspolyethylene terephthalate glycolPolyethylene TerephthalatesPolyurethanesClear alignerHeating timePET-GThermoformingThermoplastic materialsTPU

Identifiers

PMID42393668
PMCPMC13599170

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.