A high centrifugal force-enhanced Ziehl-Neelsen method for improved detection of Mycobacterium tuberculosis.

Godlove T Chaula, Lucy Namkinga, Wilber Sabiiti, Nyanda E Ntiningya, Bariki Mtafya, Ally Mahadhy

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Godlove T ChaulaMbeya Medical Research Centre, National Institute for Medical Research, Mbeya, Tanzania.
Lucy NamkingaDepartment of Biochemistry and Pharmacology, Mbeya Collage of Health and Allied Sciences, University of Dar es Salaam, Mbeya, Tanzania.
Wilber SabiitiSchool of Medicine, University of St Andrews, St. Andrews, United Kingdom.ORCID https://orcid.org/0000-0002-4742-2791
Nyanda E NtiningyaMbeya Medical Research Centre, National Institute for Medical Research, Mbeya, Tanzania.
Bariki MtafyaMbeya Medical Research Centre, National Institute for Medical Research, Mbeya, Tanzania.
Ally MahadhyDepartment of Molecular Biology and Biotechnology, College of Natural and Applied Sciences, University of Dar es Salaam, Dar es salaam, Tanzania.ORCID https://orcid.org/0000-0002-5586-7088

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ziehl-Neelsen (ZN) smear microscopy remains central to tuberculosis (TB) diagnosis and treatment monitoring; however, its sensitivity is limited by incomplete recovery of Mycobacterium tuberculosis during pre-analytical processing. This study evaluated whether modifying centrifugation force and duration improves bacillary recovery and ZN smear microscopy performance. Laboratory experiments were conducted using M. tuberculosis H37Rv suspensions and clinical sputum specimens. Following NALC-NaOH treatment, samples were centrifuged at 2,000, 3,000, and 6,000 × g for 40 min. The effect of centrifugation duration was assessed at 3,000 × g by comparing 20 and 40 min using the same M. tuberculosis H37Rv cultures and the same clinical sputum specimens at both time points, ensuring paired measurements within each sample type. Smear positivity and ZN smear grading were evaluated from replicate smears and analyzed using non-parametric statistical tests, with significance set at p < 0.05. In M. tuberculosis H37Rv suspensions, no significant differences in smear positivity or grading were observed across centrifugal forces (p = 0.368 and p = 0.212, respectively). In clinical sputum specimens, smear positivity did not differ significantly across forces (p = 0.716), whereas ZN smear grading increased significantly with higher centrifugal force (p = 0.0051). At 3,000 × g, extending centrifugation time from 20 to 40 min did not significantly affect smear positivity in either sample type (both p = 1.000). In contrast, ZN smear grading increased from 1+ to 2+ in clinical specimens with extended centrifugation time (p = 0.016), while no change was observed in M. tuberculosis H37Rv suspensions. These findings indicate that increasing centrifugal force may enhance bacillary concentration in clinical sputum, resulting in improved smear grading without a corresponding increase in detection rate. Extending centrifugation time has limited impact on smear positivity. Optimization of pre-analytical centrifugation parameters may improve ZN smear microscopy performance in clinical specimens.

Indexed as

Mycobacterium tuberculosisTuberculosisBacilloscopyCentrifugationHumansSputum

Identifiers

PMID42391193
PMCPMC13327257

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.