Evidence map›Paper›PMID 42388936›Full record

ArticleCureus2026

Technical Feasibility and Preliminary Safety Analysis of Intraoperative Electromyographic Neuromonitoring Using an Insulated Access Needle During Minimally Invasive Lumbar Pedicle Screw Fixation: A Retrospective Multicenter Series.

Fred Mo, Behnam Myers, Rajesh V Patel, Travis Greenhalgh, Bob Salvat

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Fred MoDepartment of Orthopedic Surgery, MedStar Georgetown University Hospital, Washington, USA.
Behnam MyersDepartment of Orthopedic Surgery, Nova Southeastern University, Fort Lauderdale, USA.
Rajesh V PatelDepartment of Orthopedic Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, USA.
Travis GreenhalghDepartment of Engineering, SurGenTec, Limited Liability Company, Boca Raton, USA.
Bob SalvatDepartment of Clinical Research, SurGenTec, Limited Liability Company, Boca Raton, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Triggered electromyography (t-EMG) is used as an adjunct to fluoroscopy during minimally invasive lumbar pedicle screw fixation to detect potential cortical breaches. Its diagnostic accuracy depends on the electrical isolation properties of the stimulating instrument. Standard non-insulated Jamshidi needles allow current to disperse along the full needle shaft, which may reduce signal specificity at the pedicle tip. An insulated access needle with an adjustable depth stop (ALARA™ Neuro Access Needle; SurGenTec, LLC, Boca Raton, FL, USA) was used with continuous t-EMG monitoring in this series. Screw position was assessed by biplanar fluoroscopy and final t-EMG testing only; no postoperative CT was obtained in asymptomatic patients. Methods Retrospective post-market multi-center series. Three surgeons at independent sites placed 367 percutaneous lumbar pedicle screws in 75 consecutive patients (182 spinal levels, L1-S1, 2020-2021). An ALARA needle threshold of ≥5 mA was the adopted criterion before proceeding to guidewire placement. All patients underwent postoperative neurological assessment. Results No patient sustained a new postoperative neurological deficit attributable to screw malposition. Of 367 screws, 341 (92.9%) were placed without needle repositioning; 26 (7.1%) required repositioning because of sub-threshold EMG readings. One screw (0.3%) produced persistently low EMG values (final screw reading, 9 mA at L4) consistent with possible pedicle cortical proximity; this was flagged clinically, and the patient experienced no neurological sequelae on follow-up examination. ALARA needle readings of ≥5 mA preceded final screw readings of ≥10 mA in all cases in which repositioning was not required, an empirical offset consistent with differences in stimulating surface area between the needle tip and the screw. Conclusions Use of an insulated access needle with continuous t-EMG monitoring identified and enabled real-time correction of suboptimal needle trajectories in 26 of 367 screws (7.1%) before guidewire placement, with zero postoperative neurological deficits across 75 patients at three independent surgical sites using multiple implant systems. A needle-specific threshold of ≥5 mA consistently preceded final screw readings within the published safety range across all treated lumbar and sacral levels. These findings support needle-stage t-EMG monitoring with an insulated access needle as a practical, platform-independent tool for enhancing intraoperative safety during minimally invasive surgical (MIS) lumbar pedicle screw fixation, with prospective CT-correlated studies warranted to establish definitive threshold standards.

Indexed as

insulated access needleintraoperative neuromonitoringjamshidi needlelumbar spine surgeryminimally invasive spine surgerypedicle breachpedicle screw fixationstimulation thresholdtransforaminal lumbar interbody fusion (tlif)triggered electromyography

Identifiers

PMID42388936
PMCPMC13322735

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.