Evidence map›Paper›PMID 42387515›Full record

ArticleBMC oral health2026

Fracture strength of conventional versus digital interim crowns after thermal cycling.

Işıl Sarıkaya, Tuğçe Koç, İlknur Usta Kutlu

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Işıl SarıkayaDepartment of Prosthodontics, Faculty of Dentistry, Gaziosmanpaşa University, Tokat, 60100, Turkey.
Tuğçe KoçDepartment of Prosthodontics, Faculty of Dentistry, Gaziosmanpaşa University, Tokat, 60100, Turkey. tugcekoc1004@gmail.com.
İlknur Usta KutluDepartment of Prosthodontics, Faculty of Dentistry, Gaziosmanpaşa University, Tokat, 60100, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProvisional restorations are essential components of fixed prosthodontic treatment. This study compared the fracture strength and failure modes of provisional crowns fabricated using conventional direct, conventional indirect, CAD/CAM 3D printing, and CAD/CAM milling techniques after thermal aging.

methodsA total of 48 provisional crowns were fabricated across four groups (n = 12 per group): conventional direct technique using dual-cured composite resin (Tempsmart DC, GC Corporation, Tokyo, Japan), conventional indirect technique using autopolymerized PMMA (Temdent Classic, Schütz Dental GmbH, Rosbach, Germany), CAD/CAM 3D printing using light-cured resin (ResMach Interim, ResMach, Istanbul, Turkey), and CAD/CAM milling using pre-polymerized PMMA (Acryx, Akrodent, Istanbul, Turkey). All crowns were cemented onto standardized cobalt-chromium dies and subjected to 10,000 thermocycles alternating between 5 °C and 55 °C (30-second dwell time; 5-second transfer time). Fracture strength testing was performed using a universal testing machine at a crosshead speed of 1 mm/min until failure, with maximum loads recorded in Newtons. Fracture modes were classified using Burke's classification through visual and photographic analysis. Statistical analysis was performed using one-way ANOVA and Tamhane's T2 post-hoc test (p < 0.05).

resultsThe highest fracture strength was recorded in the Acryx group (1511.67 ± 140.73 N), significantly higher than all other groups (p < 0.001). The ResMach Interim group showed the lowest fracture strength (581.62 ± 51.86 N). Conventional groups (Tempsmart DC: 716.58 ± 104.81 N; Temdent Classic: 792.85 ± 83.70 N) had intermediate values. One-way ANOVA revealed a large effect of fabrication technique on fracture strength (η² = 0.857). Acryx exhibited predominantly Class II fractures (75.0%), while other groups showed Class I fractures (83.3-100%).

conclusionsCAD/CAM-milled PMMA crowns demonstrated superior fracture resistance and more favorable ductile fracture patterns compared to conventional and 3D-printed crowns after thermal aging, suggesting these materials may be preferred for long-term provisional use in high-stress clinical scenarios such as posterior region applications.

Indexed as

Computer-Aided DesignCrownsDental Prosthesis DesignDental Restoration FailureDental Restoration, TemporaryComposite ResinsDental MaterialsDental Stress AnalysisHumansMaterials TestingPolymethyl MethacrylatePrinting, Three-DimensionalStress, MechanicalTemperatureTime FactorsComposite ResinsDental MaterialsPolymethyl MethacrylateComputer-aided designDental prosthesisPolymethyl methacrylateTemporary dental restorationThree-dimensional printing

Identifiers

PMID42387515
PMCPMC13591753