Evidence map›Paper›PMID 42384360›Full record

ArticleEuropean radiology experimental2026

Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction.

Marianna Gulizia, Clarisse Dromain, Laura Haefliger, Hussayn Chettab, Christine Chevallier, Anaïs Viry

Abstract read
In one paragraph

Article in European radiology experimental, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Marianna GuliziaDepartment of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. marianna.gulizia@chuv.ch.ORCID http://orcid.org/0000-0001-5494-2691
Clarisse DromainDepartment of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Laura HaefligerDepartment of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Hussayn ChettabDepartment of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Christine ChevallierDepartment of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Anaïs ViryInstitute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo determine the optimal low-keV level using deep learning image reconstruction (DLIR) that maximizes lesion detectability, and to assess the potential for iodinated contrast media (ICM) reduction based on detectability improvements across varying patient body habitus. MATERIALS AND

methodsAn abdominal phantom was scanned using a standard thoraco-abdomino-pelvic dual-energy computed tomography (DECT) protocol during the portal venous phase, with three rings inserted simulating different body habitus. Virtual monoenergetic images (VMI) were reconstructed from 40 to 70 keV in 10 keV increments using adaptive statistical iterative reconstruction-V (ASIR-V) 50% and high-strength DLIR (DLIR-H). Contrast enhancement was quantified, spatial resolution was evaluated with the task-based transfer function, and noise characteristics were analyzed using the noise power spectrum. Low-contrast lesion detectability (5-10 mm) was assessed using an anthropomorphic model observer.

resultsCompared to ASIR-V, DLIR-H provided equivalent contrast, reduced image noise, and improved spatial resolution. All lesion sizes with DLIR-H were technically detectable under all conditions. The reconstruction at 40 keV demonstrated the highest detectability of hypovascular lesions under all conditions. However, a decrease in detectability was observed in the large phantom relative to the small and medium phantoms, resulting in a reduced theoretical potential for iodine dose reduction. The theoretical potential for iodine dose reduction using 40 keV with DLIR-H is at least 31.3% based on the phantom-based model.

conclusionUnder phantom conditions, 40 keV with DLIR-H shows superior detectability of hypovascular lesions under all conditions, suggesting the theoretical possibility of reducing iodine load by up to 31.3%, based on modeled detectability performance. RELEVANCE STATEMENT: Based on a phantom-derived model, the combination of 40-keV VMI reconstruction with DLIR-H suggests the potential for more than 30% ICM reduction in oncologic body CT, a finding that warrants confirmation in clinical studies. KEY POINTS: Based on a phantom-derived model 40 keV VMI with DLIR-H achieved the highest detectability of hypovascular liver lesions. This approach enabled a 31.3% ICM volume reduction. Larger body habitus limits ICM volume reduction optimization margins.

Indexed as

Deep LearningImage Processing, Computer-AssistedIodineLiver NeoplasmsRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray ComputedContrast MediaHumansLiverPhantoms, ImagingRadiation DosageRadiography, Dual-Energy Scanned ProjectionContrast MediaIodineContrast mediaDeep learningLiver neoplasmsPhantoms (imaging)Tomography (x-ray computed)

Identifiers

PMID42384360
PMCPMC13323749

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.