Evidence map›Paper›PMID 42381958›Full record

ArticleJTCVS open2026

Physically validated mitral valve models for surgical simulation: Bridging anatomy, pathology, and practice.

Patrick Carnahan, Charles Yuan, John Moore, Luca Zanella, Terry Peters, Elvis Chen, Gianluigi Bisleri

Abstract read
In one paragraph

Article in JTCVS open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Patrick CarnahanImaging Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.
Charles YuanImaging Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.
John MooreImaging Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.
Luca ZanellaHeart Surgery, Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy.
Terry PetersImaging Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.
Elvis ChenImaging Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.
Gianluigi BisleriCardiac Surgery Department, St Michael's Hospital, University of Toronto, Toronto, Ontario, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Effective mitral valve repair remains significantly operator-dependent partially due to the lack of standardized training substrates. We aimed to develop a simplified, parametric mathematical model of the mitral valve apparatus and physically validate its ability to accurately recreate the geometry and hemodynamic function of both a healthy valve and specified pathological valves when tested in a dynamic pulse duplicator system. Methods: A parametric mathematical framework was employed to define the 3-dimensional saddle-shaped annulus and its leaflet architecture using core, clinically measurable geometric coefficients (eg, annular diameters and segment-specific leaflet lengths). Five distinct silicone valve replicas were manufactured to match the mathematical specifications: 2 healthy baselines and 3 Carpentier Type II Prolapse valve variants (P1, P2, and P3) induced by localized leaflet length adjustments. Each physical model was tested in a dynamic pulse duplicator under physiological pressure and flow conditions. Valve function, geometry and regurgitation severity were quantified using cardiac ultrasound. Results: Derived measurements from the physical valve replicas accurately matched expected anatomical ranges from patient cohorts. The healthy baseline models consistently demonstrated competent function with no regurgitation. Pathological models, generated solely by manipulating the core geometric coefficients (lengthened P-segment, increased annular diameter), consistently exhibited characteristic segmental prolapse and moderate to severe mitral regurgitation. The resulting functional metrics, including regurgitant jet severity, confirmed the predictable functional outcome driven by the specified geometric inputs. Conclusions: We present a physically validated, anatomically configurable mathematical model that demonstrates a direct and predictable link between core geometric parameters and mitral valve functional behavior. Unlike existing physical simulation platforms that rely on biological tissue, this approach provides a standardized, reproducible, and customizable platform for surgical training and in vitro testing of novel repair techniques for segmental mitral valve disease.

Indexed as

mathematical modelmitral valvemitral valve repairmitral valve surgerysimulationtraining

Identifiers

PMID42381958
PMCPMC13316320

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.