Evidence map›Paper›PMID 42380962›Full record

ArticleBMC oral health2026

Effects of different aligner thicknesses and expansion step sizes on maxillary arch expansion with Invisalign Palatal Expander: a three-dimensional finite element study.

Luhua Ding, Jifang Hui, Hu Qiao

Abstract read
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Luhua DingKey Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, China.
Jifang HuiKey Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, China.
Hu QiaoKey Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, China. qiaohu123@mail.xjtu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to investigate the biomechanical effects of different aligner thicknesses and expansion step sizes with the Invisalign Palatal Expander (IPE) on the midpalatal suture, teeth, and periodontal tissues during maxillary arch expansion using the finite element method (FEM), thereby facilitating its more precise and effective clinical application.

methodsThree-dimensional (3D) finite element models, including teeth, bilateral maxilla, midpalatal suture, periodontal ligament (PDL), aligner, and attachments, were constructed. Stress distribution and initial displacement of the midpalatal suture, teeth, and PDL were evaluated under three aligner thicknesses (0.5, 1.0, and 1.5 mm) and different step sizes (0.1, 0.2, and 0.3 mm).

resultsDuring expansion with the IPE, increased aligner thickness markedly enhanced the buccal displacement of posterior teeth, increased midpalatal suture initial displacement, and promoted bodily movement rather than tipping, albeit with increased PDL stress. A greater step size increased buccal displacement of the first molar but reduced that of the primary molars. Thicker aligners (≥ 1.0 mm) combined with a larger step size directed mechanical effects posteriorly to a greater degree, promoting greater suture initial displacement in the posterior region.

conclusionThe thickness of the IPE aligner is the dominant factor regulating tooth movement patterns and midpalatal suture initial displacement, while step size modulates the magnitude and distribution of the mechanical response in the posterior maxillary arch. To promote greater posterior midpalatal suture displacement, we recommend using aligners with a thickness of at least 1.0 mm in combination with an appropriately increased step size.

Indexed as

Finite Element AnalysisMaxillaOrthodontic Appliance DesignOrthodontic Appliances, RemovablePalatal Expansion TechniqueBiomechanical PhenomenaCranial SuturesDental ArchDental Stress AnalysisHumansImaging, Three-DimensionalPeriodontal LigamentStress, MechanicalAligner thicknessArch expansionExpansion step sizeFinite element methodInvisalign palatal expander

Identifiers

PMID42380962
PMCPMC13591744

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.