ArticleMicrosystems & nanoengineering2026
AlGaN/GaN HEMT H₂ sensor with integrated Wheatstone bridge and on-chip microheater for 0.1-ppm detection.
Article in Microsystems & nanoengineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Hydrogen (H₂) is a key clean-energy carrier in the transition to sustainable energy systems, but its extreme flammability and low ignition energy demand highly reliable leakage-monitoring technologies for safe deployment. This study presents a MEMS AlGaN/GaN high-electron-mobility transistor (HEMT) H₂ sensor that achieves high sensitivity and fast detection of trace hydrogen in air. The device implements a four-HEMT Wheatstone bridge-two Pd-gated sensing HEMTs and two passivated reference HEMTs-with an integrated microheater, all monolithically fabricated on a suspended GaN membrane. Pd-catalyzed H₂ dissociation and spillover lower the effective gate work function and modulate the Schottky barrier, and the differential readout suppresses common-mode drift. At 315 °C, the sensor achieves a limit of detection (LOD) of 0.1 ppm with a corresponding sensitivity of 1.48 mV/V/ppm. A combined device model and noise analysis further projects a detection limit approaching the ppb level. The baseline-corrected output is monotonic and well described by a four-parameter logistic model, thereby defining a practical, quantifiable working range of 0.1-1000 ppm (spanning four orders of magnitude). At 1000 ppm, the response and recovery times are 5.7 s and 26.2 s, respectively. The sensor exhibits high selectivity to H₂ with negligible cross-sensitivity to typical interferents (e.g., alcohols, SO₂, CH
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.