Evidence map›Paper›PMID 42375597›Full record

ArticleInternational journal of cardiology. Heart & vasculature2026

PulseSelect vs FARAPULSE pulsed field ablation: Comparative analysis of myocardial, neural-injury and hemolysis biomarkers and short-term outcomes.

Christian Gold, Anastasia Falagkari, Florian Post, Victoria Johnson, Esther Roth, Sinan Justin Kühn, Dominik Linz, Dobromir Dobrev, Julia Erath-Honold, Laura Rottner and 3 more

Abstract read
In one paragraph

Article in International journal of cardiology. Heart & vasculature, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Recent highlights from theInternational journal of cardiology. Heart & vasculature · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Christian GoldDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
Anastasia FalagkariDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
Florian PostDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
Victoria JohnsonDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
Esther RothDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
Sinan Justin KühnDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
Dominik LinzDepartment of Cardiology, Maastricht University Medical Center and Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands.
Dobromir DobrevUniversity of Duisburg-Essen Institute of Pharmacology, Essen, Germany.
Julia Erath-HonoldDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
Laura RottnerDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
David M LeistnerDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
Jana KupusovicDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.
Reza WakiliDepartment of Cardiology and Angiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Randomized trials have demonstrated safety and efficacy of pulsed field ablation (PFA) for atrial fibrillation (AF) using the FARAPULSE™ system (PFA-F). We evaluated implementation of the PulseSelect™ system (PFA-P) in a PFA-F experienced center. Methods: This single-center study included 150 consecutive patients undergoing first pulmonary vein isolation (PVI) with PFA-P ( Results: Baseline characteristics were comparable, except for a higher proportion of males in the PFA-F group. Acute PVI was comparable between groups (98% vs. 100%). Skin-to-skin time and radiation dose were similar, while fluoroscopy (14.3 vs. 11.9 min, Conclusion: Implementation of PFA-P is feasible with an evident learning curve in a PFA-F experienced center. Higher post-procedural cardiac biomarker levels may suggest a greater extent of local myocardial tissue damage after PFA-P. The impact of biomarkers on long-term outcome requires further studies.

Indexed as

Atrial fibrillationHemolysisMyocardial biomarkersPFAPulmonary vein isolationS100

Identifiers

PMID42375597
PMCPMC13310936

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.