Biomechanical evaluation of a novel cervical interfacet self-locking cage versus ACDF: a goat cadaveric study combined with human CT-based finite element analysis.
Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
backgroundAnterior cervical discectomy and fusion (ACDF) is a well-established treatment for cervical degenerative disease (CDD). Nevertheless, its anterior approach carries inherent risks to critical neck structures, prompting the exploration of posterior fusion alternatives for selected patients. Traditional anterior cervical discectomy and fusion (ACDF) for cervical degenerative disease involves navigating complex anterior neck anatomy with potential risks to critical neurovascular structures, motivating the development of safer posterior fusion alternatives.
methodsTwenty-four fresh C5-C6 segments from adult goats were randomly assigned to the intact, ACDF, and CILC groups (n = 8 per group). After confirming the anatomical similarity between goat and human cervical spines via three-dimensional reconstruction, corresponding surgical procedures were performed at the C5-C6 level. Range of motions (ROMs) in flexion-extension, lateral bending, and axial rotation were measured under a pure moment of 1.5 N·m using a material testing machine. A finite element model of C3-C7 was developed based on computed tomography data from healthy adults. ACDF and CILC procedures were simulated, with a 1 N·m moment and 73.6 N pre-load applied to analyse the stress distribution in adjacent segment discs, facet cartilage, and implants.
resultsAnatomical measurements confirmed a high similarity between goat and human C5-C6 segments (P > 0.05), validating its use as an experimental model. In biomechanical tests, both CILC and ACDF significantly reduced segmental motion (P < 0.001). Compared with ACDF, CILC demonstrated greater ROM in flexion (3.31° vs. 1.52°, P < 0.05), but superior stability in extension (1.86° vs. 3.86°) and axial rotation (left: 5.89° vs. 8.19°; right: 6.11° vs. 8.89°) (P < 0.05). Finite element analysis confirmed model reliability, demonstrating close alignment between predicted and reported ROM values. CILC generated lower or comparable stress in C3/4 and C4/5 discs compared with ACDF, but higher stress at C5/6. Moreover, CILC resulted in higher facet joint contact forces and implant stress than ACDF, particularly during flexion and extension.
conclusionAlthough CILC demonstrates biomechanical performance comparable to ACDF with specific advantages in controlling extension and axial rotation without significant advantages, its posterior minimally invasive approach effectively avoids neurovascular risks associated with anterior surgery. The device provides a safer alternative for cervical fusion, particularly in cases with complex anterior anatomy or those requiring revision surgery. However, the observed higher facet and implant stresses underscore the need for careful patient selection, particularly regarding pre-existing facet joint condition and bone quality.