ArticleJournal of imaging informatics in medicine2026
RE-LIG: A Faithfulness-Driven Layer Integrated Gradients Framework for Explainable Medical Visual Question Answering.
Article in Journal of imaging informatics in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Medical Visual Question Answering (Med-VQA) systems have the potential to support medical image interpretation and clinical decision-making processes. However, the "black-box" nature of existing systems and low-resolution constraints limit the transparency of model decisions, hindering clinical applicability. This work proposes a high-resolution holistic framework called robust and efficient layer-integrated gradients (RE-LIG) to enhance reliability and explainability in Med-VQA systems. The proposed architecture is built upon three key components: (1) high-resolution visual encoding: the PubMedCLIP encoder is scaled to high-resolution using dynamic positional embedding interpolation to capture fine details. (2) Multimodal semantic fusion: clinical questions solved by BioLinkBERT and visual features obtained by PubMedCLIP are aligned through a coattention mechanism. (3) Explainability framework: to counter the noisy nature of classical gradient methods, the RE-LIG algorithm, which combines noise tunneling and layer-based integration strategies, has been integrated into the system. Extensive experiments conducted on the SLAKE dataset demonstrate the proposed framework's success in primarily increasing model faithfulness. Quantitative analyses demonstrate that the RE-LIG method achieves a + 28.9% higher explanation fidelity (RE-LIG AOPC = 0.3180 vs. Vanilla IG = 0.2467, Bootstrap 95% CI [0.262-0.375], Wilcoxon p < 0.001) compared to standard gradient approaches. While achieving this gain in explainability, competitive performance with state-of-the-art (SOTA) models was achieved without compromising diagnostic performance (80.77% overall accuracy, 87.61% closed-ended, and 77.34% open-ended performance). Ablation studies confirm that the integrated noise reduction mechanisms shift the model's focus from background noise to actual pathological boundaries. The findings demonstrate that explainability is not merely a visual aid for clinical confidence but a measurable and verifiable requirement.
Indexed as
Identifiers
42373891What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.