ArticleSichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition2026

[A Method for Respiratory Monitoring in Thermal Infrared Video Using Masked Autoencoder Pretraining].

Rushi Mao, Xuebin Lü, Wei Zhang

Abstract readEnglish Abstract
In one paragraph

Article in Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Rushi Mao( 610041)West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu 610041, China.ORCID 0009-0008-3331-7983
Xuebin Lü( 610041)West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu 610041, China.ORCID 0000-0001-8940-7613
Wei Zhang( 610041)West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu 610041, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: By constructing spatiotemporal maps from thermal infrared videos and applying self-supervised learning methods, temperature change trends in the oral and nasal regions caused by breathing can be automatically detected, enabling long-term, non-contact breathing monitoring. This offers technical support for early warning of emotions, stress responses, and respiratory system diseases. Methods: To address the limitations of existing methods in characterizing temperature variation trends in thermal infrared, a two-stage self-supervised reconstruction spatio-temporal graph and downstream fine-tuning method is proposed. First, spatial registration between the ordinary camera and the thermal infrared camera is achieved using an affine transformation matrix, enabling key point tracking and the construction of a spatio-temporal graph. Considering individual differences in the sensitive areas of the respiratory signal, deep representations are initially extracted through self-supervised learning, and the latent vectors are then fine-tuned to adapt to downstream monitoring tasks. Additionally, two new evaluation metrics are introduced: the average absolute error of the ratio of inhaled to exhaled gas volumes and the average absolute error of respiratory duration. Results: The experimental results on the dataset show that this two-stage training method can accurately capture the trend of respiratory signals. The waveform fitting accuracy of end-to-end feature learning is significantly better than that of traditional methods and current popular models. The core performance indicators are as follows: mean absolute error 0.07 ± 0.02, root mean square error 0.69 ± 0.11, Pearson correlation coefficient 0.15 ± 0.04, ratio of inhalation to exhalation volume 0.40 ± 0.12/0.26 ± 0.05, and mean absolute error of respiratory duration 0.79 ± 0.19/0.79 ± 0.10. Conclusion: The self-supervised pre-training waveform analysis method based on a masked autoencoder demonstrates advantages in both the frequency and time domains for respiratory monitoring. Additionally, morphological differences in the pulse signal during the respiratory phase were identified. The kurtosis of the photoplethysmography (PPG) signal significantly decreased, and the skewness was reduced during the exhalation phase. This finding offers a new perspective for evaluating cardiopulmonary coupling function and autonomic nerve regulation from the morphological feature dimension of PPG.

Indexed as

RespirationThermographyAlgorithmsAutoencoderHumansInfrared RaysMonitoring, PhysiologicVideo RecordingAutoencoderMonitoring, physiologicRespiratory rate

Identifiers

PMID42369684
PMCPMC13303229

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.