Millimeter-Wave MIMO radar for contactless neonatal heart-rate assessment: performance under common resuscitation-related maneuvers and feasibility in clinical workflow.
Article in Frontiers in pediatrics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Rapid and reliable heart-rate (HR) assessment is critical during neonatal resuscitation. Contactless monitoring may serve as a valuable adjunct to conventional methods, but the clinical performance of millimeter-wave radar under routine resuscitation-related maneuvers remains unclear. We evaluated the performance and workflow feasibility of a millimeter-wave multiple-input multiple-output (MIMO) radar system for contactless neonatal HR assessment. Methods: In this single-center prospective study, we conducted two sequential experiments. In the factor-quantification experiment, 60 clinically stable neonates in the neonatal intensive care unit (NICU) were monitored simultaneously with radar and a 3-lead ECG bedside monitor as the reference. We assessed HR measurement performance under quiet baseline conditions and four simulated resuscitation-related maneuvers: drying, oronasal suctioning, auscultation, and postural change. Measurement error was quantified using root-mean-square error (RMSE), and agreement was evaluated using Bland-Altman analysis. In the real-workflow experiment, 26 neonates on a radiant warmer in the operating room were enrolled. We analyzed 115 auscultation windows by comparing mean radar-derived HR with auscultated HR at the window level and by stratifying per-second radar-derived HR errors within each window. Results: Under quiet baseline conditions, radar-derived HR showed agreement with ECG, with most RMSE values below the predefined 10-bpm descriptive benchmark. Measurement performance was relatively preserved during simulated drying, suctioning, and auscultation. In contrast, postural change significantly increased error and caused systematic HR underestimation. In the real-workflow experiment, window-level differences between mean radar-derived HR and auscultated HR within auscultation windows were centered near 0 bpm. In the per-second error analysis within auscultation windows, errors of ≤5 bpm were the most frequent category, whereas errors of >15 bpm were uncommon. Conclusion: Millimeter-wave MIMO radar showed relatively small HR measurement error for contactless short-window assessment under quiet baseline conditions, particularly when the infant remained stable and oriented toward the sensor. Postural change was the dominant source of increased measurement error and may limit reliability during thoracic reorientation. These findings support the potential role of radar as an adjunct tool for short-window HR assessment during neonatal care and resuscitation-related conditions. Continuous beat-to-beat accuracy was not validated in this study and requires further investigation using continuous ECG-based reference standards.