Evidence map›Paper›PMID 42365618›Full record

ArticleClinical and experimental dental research2026

Effect of Bonding Height on Force-Moment Generation in Orthodontic Fixed Lingual Retainers: An In Vitro Study.

Francesca Thaden, Linus Hötzel, Benedikt Dotzer, Matthias Mertmann, Andrea Wichelhaus, Hisham Sabbagh

Abstract read
In one paragraph

Article in Clinical and experimental dental research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Francesca ThadenDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Munich, Germany.
Linus HötzelDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Munich, Germany.
Benedikt DotzerDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Munich, Germany.
Matthias MertmannDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Munich, Germany.
Andrea WichelhausDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Munich, Germany.
Hisham SabbaghDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo investigate the effect of different bonding heights on force-moment generation in orthodontic fixed lingual retainers under loading in a biomechanical setup. MATERIALS AND

methodsThree commercially available lingual retainers were evaluated: two conventionally fabricated stainless-steel retainers (R1, R2) and one CAD/CAM-manufactured nickel-titanium retainer (R3). Using a biomechanical test setup, vertical forces and labiolingual moments were recorded and applied in three dimensions in response to a standardized vertical displacement of 0.3 mm. The effect of three standardized bonding heights (incisal, middle, and gingival thirds of the clinical crown) was assessed.

resultsBoth forces and moments increased with vertical loading. Statistically significant differences were observed among retainer materials, whereas bonding height did not significantly affect the outcomes. At 0.3 mm vertical displacement, the lowest force and moment were recorded for R1 bonded incisally (0.59 ± 0.37 N; 3.48 ± 0.37 Nmm), and the highest for R3 at mid-crown bonding height (1.40 ± 0.13 N; 8.70 ± 1.19 Nmm).

conclusionsRetainer type was found to have a greater influence on force and moment development than bonding height. Multistranded stainless-steel retainers may be more susceptible to deformation under occlusal loading. Further studies are required to determine the clinical relevance of bonding height in fixed lingual retainers.

Indexed as

Dental BondingOrthodontic Appliance DesignOrthodontic RetainersBiomechanical PhenomenaDental AlloysDental Stress AnalysisHumansIn Vitro TechniquesMaterials TestingNickelStainless SteelStress, MechanicalTitaniumDental AlloysNickelStainless SteelTitaniumtitanium nickelideadverse effectsbiomechanicsforceorthodontic retainertorque

Identifiers

PMID42365618
PMCPMC13310530

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked